Suppr超能文献

非妊娠患者宫颈定量应变弹性成像的可重复性及阴道米索前列醇对测量参数的影响。

Reproducibility of quantitative cervical strain elastography in nonpregnant patients and the effect of vaginal misoprostol on measured parameters.

作者信息

Mlodawski Jakub, Plusajska Justyna, Detka Karolina, Swiercz Grzegorz, Mlodawska Marta

机构信息

Collegium Medicum, Jan Kochanowski University in Kielce, Kielce, Poland.

Clinic of Obstetrics and Gynecology, Provincial Combined Hospital in Kielce, Kielce, Poland.

出版信息

Sci Rep. 2025 May 15;15(1):16857. doi: 10.1038/s41598-025-01249-y.

Abstract

Quantitative strain elastography (SE), referred to as E-Cervix (Samsung Medison), is a novel method for assessing parameters that indirectly describe the elasticity of the cervix. This evaluation yields quantitative parameters based on the analysis of the elastographic map image, which represents a new approach in the context of SE. In our study, we aimed to examine the reproducibility of this method in evaluating the cervix of non-pregnant women, the impact of basic demographic parameters of the patient on the results, and the responsiveness of the method, i.e., the assessment of changes occurring in the results after the vaginal application of a 400 µg dose of misoprostol. We included 80 patients scheduled for hysteroscopy who underwent elastographic examination using the E-Cervix module. The examination was performed twice upon admission to the department by the same ultrasonographer and then again 10-12 h after vaginal application of misoprostol, consecutively by two ultrasonographers. Our study demonstrated high reproducibility of all obtained parameters, with ICC (Intraclass Correlation Coefficient) for intraobserver variability being good to excellent, ranging from 0.85 for ECI (Elasticity index) to 0.94 for IOS (Internal Os strain)/EOS (External Os strain) ratio. For interobserver variability, ICC values ranged from 0.76 for ECI to 0.97 for IOS/EOS ratio. We observed no significant correlation between parameters such as height, weight, BMI (body mass index), and the number of births in the patient's history and the values of elastographic parameters. We found weak to moderate positive correlations between the day of the cycle in which the patient was and ECI (rho = 0.28), EOS (rho = 0.41), IOS/EOS ratio (rho = 0.33). The study observed a significant increase in the median value of the HR (Hardness ratio) parameter after the application of vaginal misoprostol (median difference = 5.32), an increase in EOS (difference of the medians = 0.04), and a significant decrease in IOS/EOS ratio (difference of medians = - 0.05). In our study, we demonstrated high reproducibility and repeatability of E-Cervix parameters in non-pregnant women and showed a negligible influence of most demographic factors on the study outcomes, as well as changes in parameter values under the influence of drugs affecting cervical elasticity. The method appears to be suitable for evaluating the cervix in non-pregnant women.

摘要

定量应变弹性成像(SE),即E-宫颈(三星麦迪逊公司),是一种评估间接描述宫颈弹性参数的新方法。该评估基于对弹性成像图图像的分析得出定量参数,这在SE领域代表了一种新方法。在我们的研究中,我们旨在检验该方法在评估非妊娠女性宫颈时的可重复性、患者基本人口统计学参数对结果的影响以及该方法的反应性,即评估阴道给予400μg米索前列醇后结果发生的变化。我们纳入了80例计划进行宫腔镜检查的患者,他们使用E-宫颈模块进行了弹性成像检查。入院时由同一名超声检查医师进行了两次检查,然后在阴道给予米索前列醇10 - 12小时后,由两名超声检查医师连续进行了两次检查。我们的研究表明,所有获得的参数具有高可重复性,观察者内变异的组内相关系数(ICC)良好至优秀,弹性指数(ECI)为0.85,内口应变(IOS)/外口应变(EOS)比值为0.94。对于观察者间变异,ICC值范围从ECI的0.76到IOS/EOS比值的0.97。我们观察到患者的身高、体重、体重指数(BMI)以及既往分娩次数等参数与弹性成像参数值之间无显著相关性。我们发现患者所处月经周期的天数与ECI(rho = 0.28)、EOS(rho = 0.41)、IOS/EOS比值(rho = 0.33)之间存在弱至中度正相关。该研究观察到阴道给予米索前列醇后硬度比值(HR)参数的中位数显著增加(中位数差异 = 5.32),EOS增加(中位数差异 = 0.04),IOS/EOS比值显著降低(中位数差异 = -0.05)。在我们的研究中,我们证明了E-宫颈参数在非妊娠女性中的高可重复性和可重复性,并表明大多数人口统计学因素对研究结果的影响可忽略不计,以及在影响宫颈弹性的药物作用下参数值的变化。该方法似乎适用于评估非妊娠女性的宫颈。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/85e1/12081600/4e00bf35e2f1/41598_2025_1249_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验