Real-time peri-operative microcalcification detection in superficial breast tissues.

作者信息

van der Stel Stefan D, Niemitz Lorenzo, Sørensen Simon, Feenstra Lianne, Andersson-Engels Stefan, Sterenborg Henricus J C M, Ruers Theo J M, Burke Ray

机构信息

Department of Surgery, Netherlands Cancer Institute-Antoni van Leeuwenhoek, Amsterdam, The Netherlands.

Group Nanobiophysics, Faculty TNW, Twente University, Enschede, The Netherlands.

出版信息

Sci Rep. 2025 May 16;15(1):17029. doi: 10.1038/s41598-025-01629-4.

Abstract

Surgical management of ductal carcinoma in situ (DCIS), particularly in cases involving suspicious morphology and orientation of microcalcifications, remains a primary treatment option. However, the lack of real-time technical assistance in the form of an intraoperative surgical tool for detection of microcalcifications in the resection margins presents a significant challenge. In the context of breast conserving surgery, ex-vivo imaging of excised breast tissues slices from 12 patients was conducted. By employing a cross-polarized multispectral microcamera setup for tissue visualization an imaging depth of up to 2 mm was achieved. The microcamera provides the clinician with a clear color image with magnification allowing features down to 50 μm to be seen on the resection surface. Mammography images were used for accurate cross-correlation, enabling the identification of microcalcifications in the microcamera images. Detection efficacy of microcalcifications in microcamera images was notably influenced by both calcification clustering and distribution depth within the tissue. Calcifications within the 2 mm range were detected through their distinct optical manifestations in relation to the adjacent tissues. Four independent reviewers-two medical and two technical-achieved an average sensitivity of 77.8%, specificity of 80.0%, and overall accuracy of 79.0%. This study demonstrates the potential of an integrated microcamera and cross-polarized setup for non-invasive, real-time detection of microcalcifications in superficial breast tissues. By focusing on the superficial 2 mm, this approach shows promising results and offers substantial opportunities for future research and clinical applications.

摘要

导管原位癌(DCIS)的手术管理,尤其是在涉及微钙化形态和方向可疑的病例中,仍然是主要的治疗选择。然而,缺乏用于检测切除边缘微钙化的术中手术工具形式的实时技术辅助是一项重大挑战。在保乳手术的背景下,对12例患者切除的乳腺组织切片进行了离体成像。通过采用用于组织可视化的交叉偏振多光谱微型相机设置,实现了高达2毫米的成像深度。微型相机为临床医生提供了清晰的彩色图像,具有放大功能,可在切除表面看到低至50微米的特征。乳腺钼靶图像用于精确的交叉关联,从而能够识别微型相机图像中的微钙化。微型相机图像中微钙化的检测效果受到钙化聚集和组织内分布深度的显著影响。通过其与相邻组织不同的光学表现检测到2毫米范围内的钙化。四位独立评审员(两名医学专家和两名技术专家)的平均灵敏度为77.8%,特异性为80.0%,总体准确率为79.0%。本研究证明了集成微型相机和交叉偏振设置在无创、实时检测浅表乳腺组织微钙化方面的潜力。通过聚焦于浅表2毫米,这种方法显示出有前景的结果,并为未来的研究和临床应用提供了大量机会。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9132/12084397/0a65594a3792/41598_2025_1629_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验