Suppr超能文献

Intracolonic Migration of a Dislocated Acetabular Cup Prosthesis.

作者信息

Lubka Jack R, Tamboli Cyrus, Brunetti Philip, Tamboli Sarosh, Davis Alex, Patel Hamish, Oyesanmi Olugbenga, Strobbe Michael, Thakore Shaival, Misra Subhasis, Mino Jeffrey

机构信息

University of South Florida Morsani College of Medicine, Tampa, Florida.

HCA Florida Bayonet Point Hospital, Hudson, Florida.

出版信息

HCA Healthc J Med. 2025 Apr 1;6(2):157-161. doi: 10.36518/2689-0216.1506. eCollection 2025.

Abstract

BACKGROUND

Acetabular cup migration is a rare complication of hip replacement surgery. If the acetabular socket of the ilium is weak, the prosthesis can erode or pass through it. There have been multiple reports of acetabular cup prosthesis migration to the colon, creating a coloarticular fistula between the hip joint and the cecum, sigmoid colon, or rectum. We report a rare presentation of a complete intracolonic migration of a prosthetic acetabular cup without creating a fistula.

CASE PRESENTATION

A 53-year-old female patient with a remote history of a total right hip replacement presented with abdominal pain and rectal bleeding. Computed tomography imaging revealed that the acetabular cup prosthesis was inside the colon. The patient underwent a colonoscopy as well as exploratory abdominal surgery, and the object was retrieved. The patient recovered without complications from the surgery. The acetabular cup migrated into the colon without formation of a residual fistula or any notable complications involving the hip joint despite the loss of the acetabular component.

CONCLUSION

The mechanism is unknown for how the acetabular prosthesis was able to pass from the hip joint into the colon, without a fistula, bowel perforation, or significant hip injury. At the time of writing, this case appears to be the first to document a complete intracolonic migration of a hip prosthesis.

摘要

相似文献

1
Intracolonic Migration of a Dislocated Acetabular Cup Prosthesis.
HCA Healthc J Med. 2025 Apr 1;6(2):157-161. doi: 10.36518/2689-0216.1506. eCollection 2025.
2
Total hip arthroplasty for post-firearm hip arthritis complicated by coloarticular fistula: A case report.
Chin J Traumatol. 2023 Nov;26(6):369-374. doi: 10.1016/j.cjtee.2023.04.004. Epub 2023 Apr 15.
3
Caecal perforation secondary to intrapelvic migration of a total hip prosthesis: A case report and a review of the literature.
Int J Surg Case Rep. 2024 Oct;123:110217. doi: 10.1016/j.ijscr.2024.110217. Epub 2024 Aug 28.
4
[Oblong acetabular cup, type TC, for revision total hip arthroplasty].
Acta Chir Orthop Traumatol Cech. 2012;79(6):506-11.
5
What Are the Functional, Radiographic, and Survivorship Outcomes of a Modified Cup-cage Technique for Pelvic Discontinuity?
Clin Orthop Relat Res. 2024 Dec 1;482(12):2149-2160. doi: 10.1097/CORR.0000000000003186. Epub 2024 Jul 9.
9
Revision of a Failed Primary Total Hip Arthroplasty following Excessive Reaming with a Medial Cup Protrusion.
Medicina (Kaunas). 2022 Sep 10;58(9):1254. doi: 10.3390/medicina58091254.
10
Imaging study of aseptic loosening of the acetabular cup after cementless total hip arthroplasty: a retrospective study.
BMC Musculoskelet Disord. 2025 Apr 21;26(1):396. doi: 10.1186/s12891-025-08607-x.

本文引用的文献

1
A rare presentation of haematuria: hip prosthesis in the bladder.
BMJ Case Rep. 2018 Mar 22;2018:bcr-2017-222831. doi: 10.1136/bcr-2017-222831.
2
Coloarticular fistula: A rare complication of revision total hip arthroplasty.
Radiol Case Rep. 2015 Nov 6;6(3):533. doi: 10.2484/rcr.v6i3.533. eCollection 2011.
5
An unusual cause of gastrointestinal bleeding-migration of a hip prosthesis.
QJM. 2015 Feb;108(2):171-2. doi: 10.1093/qjmed/hcu172. Epub 2014 Aug 18.
6
Total hip arthroplasty revision in case of intra-pelvic cup migration: designing a surgical strategy.
Orthop Traumatol Surg Res. 2011 Apr;97(2):191-200. doi: 10.1016/j.otsr.2010.10.003. Epub 2011 Mar 2.
7
Intrapelvic complications after total hip arthroplasty failure.
Am J Surg. 2002 Jan;183(1):75-9. doi: 10.1016/s0002-9610(01)00845-5.
8
Fistula between a total hip arthroplasty and the rectum: a case report.
Clin Orthop Relat Res. 2001 Jul(388):143-6. doi: 10.1097/00003086-200107000-00021.
9
Fistula between the hip and the sigmoid colon after total hip arthroplasty. A case report.
J Bone Joint Surg Am. 1997 Aug;79(8):1240-2. doi: 10.2106/00004623-199708000-00018.
10
Subhepatic migration of a hip prosthesis.
J Bone Joint Surg Br. 1996 Jan;78(1):152-3.