Iodence Ashley E, Verpaalen Valentine D, Hinson Whitney D, Budsberg Steven C
Department of Small Animal Medicine and Surgery, University of Georgia College of Veterinary Medicine, Athens, Georgia, USA.
Vet Surg. 2025 Jul;54(5):822-830. doi: 10.1111/vsu.14272. Epub 2025 May 19.
To quantify the incidence, extent, and distribution of iatrogenic articular cartilage injury (IACI) during canine elbow arthroscopy and to investigate the effect of arthroscope size on IACI.
Experimental study.
A total of 72 elbows from fresh frozen large breed canine cadavers.
Elbows were alternately assigned to nine groups consisting of different combinations of arthroscope size (1.9, 2.4, 2.7 mm) and surgeon experience (novice, intermediate, advanced). Routine arthroscopic exploration of the elbow was performed. Number of obturator insertions and procedure time were recorded. Joints were disarticulated and stained with India ink. The incidence and total surface area of IACI were determined. A linear mixed model was used to evaluate the effect of arthroscope size on IACI, procedure time, and number of obturator insertions.
The incidence of IACI was 100% with a median affected surface area of 10.6 mm (interquartile range [IQR]: 6.4-15.6). Median IACI was lowest for the 2.4 mm arthroscope, which was significantly less than the 2.7 mm arthroscope (p = .006). There were no significant differences in number of obturator insertions per arthroscope size (p = .96). Procedure time was significantly longer with the 1.9 mm than the 2.7 mm arthroscope (p = .03).
Routine arthroscopic joint exploration resulted in IACI in 100% of elbows. The 2.4 mm arthroscope was associated with the lowest extent of IACI.
Surgeons should be aware that IACI occurs routinely during canine elbow arthroscopy. Further research is warranted to investigate clinical significance and to develop methods that minimize IACI during canine elbow arthroscopy.
量化犬肘关节镜检查期间医源性关节软骨损伤(IACI)的发生率、范围和分布,并研究关节镜尺寸对IACI的影响。
实验研究。
来自新鲜冷冻大型犬尸体的72个肘关节。
将肘关节交替分配到9组,每组由关节镜尺寸(1.9、2.4、2.7毫米)和外科医生经验(新手、中级、高级)的不同组合组成。对肘关节进行常规关节镜探查。记录闭孔器插入次数和手术时间。将关节离断并用印度墨水染色。确定IACI的发生率和总表面积。使用线性混合模型评估关节镜尺寸对IACI、手术时间和闭孔器插入次数的影响。
IACI的发生率为100%,中位受影响表面积为10.6平方毫米(四分位间距[IQR]:6.4 - 15.6)。2.4毫米关节镜的中位IACI最低,显著低于2.7毫米关节镜(p = 0.006)。每种关节镜尺寸的闭孔器插入次数无显著差异(p = 0.96)。1.9毫米关节镜的手术时间明显长于2.7毫米关节镜(p = 0.03)。
常规关节镜关节探查导致100%的肘关节出现IACI。2.4毫米关节镜与最低程度的IACI相关。
外科医生应意识到在犬肘关节镜检查期间经常发生IACI。有必要进一步研究以调查其临床意义,并开发在犬肘关节镜检查期间将IACI降至最低的方法。