Suppr超能文献

二维剪切波弹性成像在鉴别淋巴结恶性病变中的诊断价值:一项前瞻性研究。

The diagnostic value of two-dimensional shear-wave elastography in identifying malignant lesions in lymph nodes: a prospective study.

作者信息

Chen Jing, Deng Yao, Xiong Jiajia, Li WenQu, Shang Gongqun, Li Hui, Wu Yu, Qin Xiaojuan

机构信息

Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.

Hubei Province Clinical Research Center for Medical Imaging, Wuhan, 430022, China.

出版信息

Sci Rep. 2025 May 19;15(1):17395. doi: 10.1038/s41598-025-00502-8.

Abstract

This study evaluates the diagnostic performance of two-dimensional shear wave elastography (2D-SWE) in differentiating between benign, metastatic lymph nodes (LNs) and lymphomas. From May 2022 to February 2023, a total of 137 patients who presented with unexplained LN enlargement were examined at the Ultrasound Medical Department of Union Hospital of Huazhong University of Science and Technology. The conventional ultrasound recorded the location, longitudinal diameter, transverse diameter, L/T ratio, blood supply mode, lymphatic hilum and 2D-SWE calculated the average elasticity (E) of LN. Histopathology was the diagnostic gold standard. A total of 124 patients with 159 superficial LNs were included (32 benign, 70 metastatic, 57 lymphoma). Malignant LNs had significantly higher E values than benign ones (49.38 ± 29.96 kPa vs. 25.00 ± 14.42 kPa, P < 0.001). When E > 25.46 kPa, the AUC, sensitivity, specificity, PPV, NPV and accuracy were 0.807, 0.787, 0.750, 0.926, 0.471 and 0.780, respectively, in identifying malignant LNs. For distinguishing benign LNs from lymphoma, the E cutoff was 25.03 kPa, with the AUC, sensitivity, specificity, PPV, NPV and accuracy of 0.727, 0.754, 0.719, 0.827, 0.622 and 0.742, respectively. To differentiate benign from metastatic LNs, an E cutoff of 36.97 kPa yielded an AUC, sensitivity, specificity, PPV, NPV and accuracy of 0.872, 0.757, 0.875, 0.930, 0.622 and 0.794, respectively. Comparing lymphoma and metastatic LNs, the E cutoff was 42.57 kPa. And the AUC, sensitivity, specificity, PPV, NPV and accuracy were 0.787, 0.700, 0.860, 0.860, 0.700 and 0.772, respectively. 2D-SWE parameter (the average elasticity) can effectively evaluate benign, metastatic LNs and lymphoma, which provides valuable information for preoperative evaluation of superficial LNs.

摘要

本研究评估二维剪切波弹性成像(2D-SWE)在鉴别良性、转移性淋巴结(LN)与淋巴瘤方面的诊断性能。2022年5月至2023年2月,华中科技大学协和医院超声医学科对137例出现不明原因LN肿大的患者进行了检查。常规超声记录LN的位置、纵径、横径、L/T比值、血供模式、淋巴门,2D-SWE计算LN的平均弹性(E)。组织病理学为诊断金标准。共纳入124例患者的159个浅表LN(32个良性、70个转移性、57个淋巴瘤)。恶性LN的E值显著高于良性LN(49.38±29.96kPa对25.00±14.42kPa,P<0.001)。当E>25.46kPa时,在识别恶性LN方面,曲线下面积(AUC)、灵敏度、特异度、阳性预测值(PPV)、阴性预测值(NPV)和准确率分别为0.807、0.787、0.750、0.926、0.471和0.780。为区分良性LN与淋巴瘤,E临界值为25.03kPa,AUC、灵敏度、特异度、PPV、NPV和准确率分别为0.727、0.754、0.719、0.827、0.622和0.742。为区分良性与转移性LN,E临界值为36.97kPa时,AUC、灵敏度、特异度、PPV、NPV和准确率分别为0.872、0.757、0.875、0.930、0.622和0.794。比较淋巴瘤与转移性LN,E临界值为42.57kPa。AUC、灵敏度、特异度、PPV、NPV和准确率分别为0.787、0.700、0.860、0.860、0.700和0.772。2D-SWE参数(平均弹性)可有效评估良性、转移性LN和淋巴瘤,为浅表LN的术前评估提供有价值的信息。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c8e2/12089400/e2334bed99ab/41598_2025_502_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验