Suppr超能文献

用胎儿心脏量化技术评估主动脉缩窄

Assessing Coarctation of the Aorta With Fetal Heart Quantification Technology.

作者信息

Yang Jiaojiao, Tan Fang, Shen Yuqin, Zhao Yuan, Xia Yan, Fan Sihan, Ji Xueqin

机构信息

Department of Obstetrics and Gynecology Center, General Hospital of Ningxia Medical University, Yinchuan, Ningxia 750003, China.

Ultrasound Medicine Department, Xian Yang Central Hospital, Xianyang, Shaanxi 712099, China.

出版信息

Matern Fetal Med. 2024 Jul 3;6(3):147-155. doi: 10.1097/FM9.0000000000000231. eCollection 2024 Jul.

Abstract

OBJECTIVE

To use fetal heart quantification () technology to compare the coarctation of the aorta (CoA) and normal fetal heart structure and systolic function and to assess whether there are abnormalities in the fetal heart structure and systolic function associated with CoA.

METHODS

This prospective cohort study was conducted from May 2020 to December 2022 and involved 18-40-week-old singleton pregnancies and 30 fetuses diagnosed with CoA using fetal echocardiography at the General Hospital of Ningxia Medical University and Peking University First Hospital Ningxia Women's and Children's Hospital, China. The control group contained 60 normal fetuses. The following parameters were recorded and analyzed statistically: four-chamber view (4CV) end-diastolic long diameter, 4CV epicardial-contralateral epicardial transverse maximum diameter, 4CV global sphericity index (GSI), left ventricular (LV) and right ventricular (RV) 24-segment end-diastolic diameter (EDD), 24-segment sphericity index (SI), LV-fractional area change (LV-FAC), LV-longitudinal strain (LV-LS), RV-fractional area change (RV-FAC), RV-longitudinal strain (RV-LS), and LV and RV 24-segment transverse fractional shortening (FS). Measurement data were compared between the two groups using an independent sample test, with < 0.05 indicating statistically significant differences. Moreover, the correlation between gestational age and GSI, LV-FAC, LV-LS, RV-FAC, and RV-LS was assessed.

RESULTS

Within and between observer comparisons of the parameters associated with major cardiac function revealed an intragroup correlation coefficient of >0.9, indicating high consistency, and a coefficient of variable of <1%, indicating low variability. Correlation analysis revealed no obvious correlation between gestational age and GSI, LV-FAC, LV-LS, RV-FAC, and RV-LS. A comparison of the four-chamber morphological structural parameters of the hearts in the two groups revealed that when compared with the control group, the 4CV end-diastolic long diameter was shortened in fetuses in the CoA group and the epicardial-contralateral epicardial transverse maximum diameter was wider, while the GSI was lower ( < 0.05). A comparison of the LV and RV morphological structure parameters between the two groups revealed that when compared with the control group, the LV's 24-segment EDD was smaller in the CoA group, the RV's 24-segment EDD was greater in the control group, the SI of the LV's segments 16-24 was greater than in the control group, and the SI of the RV's segments 7-24 was less than in the control group (all < 0.05). When compared with fetuses in the control group, the LV's segments 16-24 were greater in the CoA group, whereas the RV's segment 6-24 was smaller ( < 0.05). When compared with the control group, LV-FAC, RV-FAC, and LS were lower in the CoA group ( < 0.05). The FS of the LV segments 1-24 and the FS of the RV segments 1-16 were smaller in the CoA group than in the normal group ( < 0.05).

CONCLUSION

, a new simple technique that offers rapid analysis and high repeatability, can quantitatively evaluate structural and systolic function changes in fetuses with CoA.

摘要

目的

运用胎儿心脏定量分析技术比较主动脉缩窄(CoA)胎儿与正常胎儿的心脏结构及收缩功能,评估CoA胎儿心脏结构和收缩功能是否存在异常。

方法

本前瞻性队列研究于2020年5月至2022年12月进行,纳入中国宁夏医科大学总医院及北京大学第一医院宁夏妇女儿童医院18至40周单胎妊娠孕妇,其中30例胎儿经胎儿超声心动图诊断为CoA。对照组包含60例正常胎儿。记录并统计分析以下参数:四腔心切面(4CV)舒张末期长径、4CV心外膜-对侧心外膜横向最大径、4CV整体球形指数(GSI)、左心室(LV)和右心室(RV)24节段舒张末期直径(EDD)、24节段球形指数(SI)、LV面积变化分数(LV-FAC)、LV纵向应变(LV-LS)、RV面积变化分数(RV-FAC)、RV纵向应变(RV-LS)以及LV和RV 24节段横向缩短分数(FS)。两组间测量数据采用独立样本t检验进行比较,P<0.05表示差异有统计学意义。此外,评估孕周与GSI、LV-FAC、LV-LS、RV-FAC及RV-LS之间的相关性。

结果

主要心功能相关参数在观察者内及观察者间比较显示,组内相关系数>0.9,表明一致性高,变异系数<1%,表明变异性低。相关性分析显示孕周与GSI、LV-FAC、LV-LS、RV-FAC及RV-LS之间无明显相关性。两组心脏四腔心形态结构参数比较显示,与对照组相比,CoA组胎儿4CV舒张末期长径缩短,心外膜-对侧心外膜横向最大径增宽,而GSI较低(P<0.05)。两组LV和RV形态结构参数比较显示,与对照组相比,CoA组LV的24节段EDD较小,对照组RV的24节段EDD较大,LV第16至24节段的SI大于对照组,RV第7至24节段的SI小于对照组(均P<0.05)。与对照组胎儿相比,CoA组LV的第16至24节段较大,而RV第6至24节段较小(P<0.05)。与对照组相比,CoA组LV-FAC、RV-FAC及LS较低(P<0.05)。CoA组LV第1至24节段的FS及RV第1至16节段的FS低于正常组(P<0.05)。

结论

胎儿心脏定量分析技术是一种新的简单技术,可快速分析且重复性高,能够定量评估CoA胎儿的结构和收缩功能变化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c7c2/12087882/e079570062bf/mfm-6-147-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验