Malling H J
Allergy. 1985 Jul;40(5):354-62. doi: 10.1111/j.1398-9995.1985.tb00247.x.
To determine reproducibility and the optimal way of expressing skin sensitivity, simultaneous skin prick tests (SPT) and intradermal tests (ICT) were performed on 25 mould-allergic patients. The patients had a well-documented history of allergy to Cladosporium and Alternaria and were tested with partially purified standardized extracts of these two mould species. Skin prick tests were carried out on the volar side of the forearm and intradermal tests on the backs of the patients. The skin tests were performed as titration using quadruplicate determinations of 10-fold allergen dilutions. The area of the skin reactions measured by planimetry were plotted in a log-log system as a function of the allergen concentration. The reproducibility (SD/mean area X 100%) of the ICTs was significantly higher than that of the SPTs (17% versus 29%). A very low reproducibility was found with wheal areas less than 5 mm2. The dose response curve of the SPT wheal area was steeper than that obtained with ICT, both concerning ICT wheal and flare. Increasing the allergen concentration with a factor 10 resulted in a doubling of the wheal area in SPT, in contrast to a factor 1.7 using ICT. The coefficient of correlation using linear regression on the dose response curve was always higher than 0.9 with SPT and ICT wheal, but significantly lower with ICT flare. Skin sensitivity was estimated as end-point and histamine equivalent reaction. No significant correlation between SPT and ICT end-point titration was found contrary to the histamine equivalent reaction.(ABSTRACT TRUNCATED AT 250 WORDS)
为了确定重复性以及表达皮肤敏感性的最佳方式,对25例霉菌过敏患者同时进行了皮肤点刺试验(SPT)和皮内试验(ICT)。这些患者有明确的对枝孢菌和链格孢菌过敏的病史,并使用这两种霉菌的部分纯化标准化提取物进行检测。皮肤点刺试验在前臂掌侧进行,皮内试验在患者背部进行。皮肤试验采用10倍变应原稀释液的四重测定进行滴定。通过平面测量法测量的皮肤反应面积在对数-对数系统中绘制为变应原浓度的函数。皮内试验的重复性(标准差/平均面积×100%)显著高于皮肤点刺试验(分别为17%和29%)。发现风团面积小于5平方毫米时重复性非常低。皮肤点刺试验风团面积的剂量反应曲线比皮内试验获得的曲线更陡,无论是皮内试验的风团还是红晕。变应原浓度增加10倍导致皮肤点刺试验中风团面积加倍,相比之下皮内试验为1.7倍。使用剂量反应曲线上的线性回归,皮肤点刺试验和风团皮内试验的相关系数始终高于0.9,但皮内试验红晕的相关系数显著较低。皮肤敏感性通过终点和组胺等效反应进行评估。与组胺等效反应相反,未发现皮肤点刺试验和皮内试验终点滴定之间存在显著相关性。(摘要截短于250字)