BACKGROUND

Antibiotics are used in periodontal therapy in selected cases, but therapy is rarely guided by antimicrobial susceptibility testing (AST). Direct AST of the oral microbiota using a combination disk with different antibiotics could provide a new way of AST to guide treatment planning.

METHODS

We performed AST of 46 strains of , , , and , with a combination disk of amoxicillin (AMX) and metronidazole (MET). The AMX-MET was compared to the largest inhibition zone diameter (IZD) obtained with AMX or MET disks, using an ordinary least square linear regression model.

RESULTS

The IZD of the AMX-MET correlated with the AMX for (interception 0.3) and with the MET for (interceptions -1.25). For , the AMX-MET was compared to AMX and MET after 20 and 44 h resulting in a superior correlation after 20 h (interception 0.06 vs 6.61 after 44 h). For , the AMX-MET was compared to MET after 44 h resulting in an inferior correlation (interception 16.65).

CONCLUSION

The IZD of AMX-MET was comparable to that of AMX and MET for important periodontal pathogens, which opens for studies on direct AST of oral samples with a mixed microbiota.

KEY MESSAGE

The amoxicillin-metronidazole disk for antimicrobial susceptibility testing results in comparable inhibition zone diameters to that of AMX and MET for important periodontal pathogens.

摘要

背景

在特定情况下,抗生素用于牙周治疗,但治疗很少以抗菌药物敏感性测试(AST)为指导。使用含不同抗生素的联合药敏纸片对口腔微生物群进行直接AST可为指导治疗方案提供一种新的AST方法。

方法

我们用阿莫西林(AMX)和甲硝唑(MET)联合药敏纸片对46株[具体细菌名称未给出]进行了AST。使用普通最小二乘线性回归模型,将AMX-MET与用AMX或MET药敏纸片获得的最大抑菌圈直径(IZD)进行比较。

结果

AMX-MET的IZD与[某种细菌]的AMX相关(截距0.3),与[另一种细菌]的MET相关(截距-1.25)。对于[又一种细菌],在20小时和44小时后将AMX-MET与AMX和MET进行比较,结果在20小时后相关性更好(截距0.06,44小时后为6.61)。对于[再一种细菌],在44小时后将AMX-MET与MET进行比较,结果相关性较差(截距16.65)。

结论

对于重要的牙周病原体,AMX-MET的IZD与AMX和MET的IZD相当,这为研究对含有混合微生物群的口腔样本进行直接AST开辟了道路。

关键信息

用于抗菌药物敏感性测试的阿莫西林-甲硝唑药敏纸片对重要牙周病原体产生的抑菌圈直径与AMX和MET相当。