Bae Kkot-Byeol, Choi Jae-Yoon, Cho Young-Tae, Lee Bin-Na, Chang Hoon-Sang, Hwang Yun-Chan, Oh Won-Mann, Hwang In-Nam
Department of Conservative Dentistry, School of Dentistry, Chonnam National University, Gwangju, Korea.
Department of Basic Science, School of Engineering, Jeonju University, Jeonju, Korea.
Restor Dent Endod. 2025 May;50(2):e19. doi: 10.5395/rde.2025.50.e19. Epub 2025 May 21.
This study aimed to evaluate the stress distribution in teeth restored with different post materials and bonding conditions using finite element analysis (FEA).
A two-dimensional FEA model of a maxillary central incisor restored with IPS-Empress-2 crown (Ivoclar Vivadent), composite resin core, and posts were created. The model simulated bonded and non-bonded conditions for both fiber-reinforced composite (FRC) and titanium (Ti) posts. Stress distribution was analyzed using ANSYS 14.0 software under a 100-N load applied at a 45° angle to the long axis of the tooth.
The results revealed that stress concentration was significantly higher in non-bonded posts compared to bonded ones. FRC posts exhibited stress values closer to those of dentin, whereas Ti posts demonstrated higher stress concentration, particularly in non-bonded states, increasing the potential risk of damage to surrounding tissues.
FRC posts, with elastic properties similar to dentin and proper adhesion, minimize stress concentration and potential damage to surrounding tissues. Conversely, materials with higher elastic modulus like Ti, can cause unfavorable stress concentrations if not properly bonded, emphasizing the importance of post adhesion in tooth restoration.
本研究旨在通过有限元分析(FEA)评估使用不同桩核材料及粘结条件修复的牙齿中的应力分布情况。
建立了一个二维有限元分析模型,该模型为一颗用上颌中切牙,使用IPS-Empress-2全瓷冠(义获嘉伟瓦登特公司)、复合树脂核和桩核进行修复。该模型模拟了纤维增强复合材料(FRC)桩和钛(Ti)桩的粘结和非粘结情况。使用ANSYS 14.0软件在与牙齿长轴呈45°角施加100 N载荷的条件下分析应力分布。
结果显示,与粘结桩相比,非粘结桩中的应力集中明显更高。FRC桩的应力值更接近牙本质,而Ti桩表现出更高的应力集中,尤其是在非粘结状态下,增加了对周围组织造成损伤的潜在风险。
FRC桩具有与牙本质相似的弹性特性且粘结良好,可将应力集中和对周围组织的潜在损伤降至最低。相反,像Ti这种具有较高弹性模量的材料,如果粘结不当,会导致不利的应力集中,这凸显了桩核粘结在牙齿修复中的重要性。