Jeong Sun Young, Gupta Nigel, Qu Zhilin, Ji Sen
Department of Cardiology Kaiser Permanente Los Angeles Medical Center Los Angeles California USA.
Department of Cardiac Electrophysiology Kaiser Permanente Los Angeles Medical Center Los Angeles California USA.
J Arrhythm. 2025 Jun 11;41(3):e70103. doi: 10.1002/joa3.70103. eCollection 2025 Jun.
Accurate interpretation of the distal bipolar electrogram (bi-EGM) is essential for successful ablation of idiopathic focal PVC. Sharp, early, and fractionated bi-EGM is often considered to be near-field and targeted, but in an empiric fashion rather than by quantitative criteria.
To quantify the distal bi-EGM with five parameters to elucidate quantitative criteria distinguishing near-field from far-field bi-EGM.
The distal bi-EGM was quantified and analyzed using: half time of activation ( ), slope factor (, derived by fitting the Boltzmann equation), linear slope (), time from onset of bi-EGM to surface ECG ( ) and number of deflections (#).
Among 41 patients, 26 were ablated successfully and 15 unsuccessfully. and , defining the sharpness of the activation process, were significantly different between the two groups (3.2 ± 0.3 vs. 5.9 ± 0.6 ms, < 0.001 and 0.8 ± 0.1 vs. 4.8 ± 2.0, = 0.01). was earlier in the successful group (35.6 ± 1.3 vs. 25.8 ± 1.6 ms, 0.01). and were not statistically different (0.2 ± 0.04 vs. 0.1 ± 0.02 mV/ms, = 0.06; and 2.7 ± 0.2 vs. 2.3 ± 0.3, = 0.22). The 5 parameters showed indifference across anatomic locations. AUCs of ROC curve are >0.8 ( 0.85, 0.85 and 0.87).
, and are precise in quantifying the sharpness and earliness of distal bi-EGM; therefore, discriminating the near-field from far-field bi-EGM for guiding successful ablation.
准确解读远端双极电图(bi-EGM)对于特发性局灶性室性早搏的成功消融至关重要。尖锐、早期且碎裂的bi-EGM通常被认为是近场且可靶向的,但这往往是凭经验而非依据定量标准。
用五个参数对远端bi-EGM进行量化,以阐明区分近场与远场bi-EGM的定量标准。
使用以下参数对远端bi-EGM进行量化和分析:激活半衰期()、斜率因子(,通过拟合玻尔兹曼方程得出)、线性斜率()、从bi-EGM起始到体表心电图的时间()以及偏转次数(#)。
41例患者中,26例成功消融,15例未成功。定义激活过程锐度的和在两组间有显著差异(3.2±0.3对5.9±0.6毫秒,<0.001;0.8±0.1对4.8±2.0,=0.01)。在成功组中更早(35.6±1.3对25.8±1.6毫秒,0.01)。和无统计学差异(0.2±0.04对0.1±0.02毫伏/毫秒,=0.06;2.7±0.2对2.3±0.3,=0.22)。这5个参数在不同解剖位置无差异。ROC曲线的AUC大于0.8(0.85,0.85和0.87)。
、和在量化远端bi-EGM的锐度和早期性方面很精确;因此,可以区分近场与远场bi-EGM以指导成功消融。