Yıldız Serap Süzük, Tavukcu Esra, Ölmez Mert Emre, Şahin Sevgi, Tek Habibe Kurtaran, Hekimoğlu Can Hüseyin, Güreser Ayşe Semra, Mumcuoğlu İpek, Dal Tuba
Department of Clinical Microbiology, University of Health Sciences Dr. Abdurrahman Yurtaslan Ankara Oncology Training and Research Hospital, Ankara, Turkey.
Department of Clinical Microbiology, University of Health Sciences Dr. Abdurrahman Yurtaslan Ankara Oncology Training and Research Hospital, Ankara, Turkey.
Diagn Microbiol Infect Dis. 2025 Oct;113(2):116937. doi: 10.1016/j.diagmicrobio.2025.116937. Epub 2025 Jun 4.
Early diagnosis and effective treatment of bloodstream infections significantly improve prognosis. The European Committee on Antimicrobial Susceptibility Testing (EUCAST) has developed rapid antimicrobial susceptibility testing(RAST) based on the disk diffusion method. In the present study, we compared the data from the RAST study from positive blood cultures in the Autobio BC (Autobio-diagnostics, Zhengzhou, Chinese) blood culture system with those obtained using the standard disk diffusion method. A total of 234 spiked blood culture samples (Klebsiella penumoniae [n= 50], Escherichia coli [n= 50], Acinetobacter baumannii [n= 20], Pseudomonas aeruginosa [n= 13], Staphylococcus aureus [n= 51], and Enterococcus spp. [n= 50]) were collected. The RAST test was performed on positive bottles, and the results were measured at 4, 8, and 20 h. Standard disk diffusion (sDD) was performed, and zone diameters were measured from subculture samples obtained from blood culture bottles. The RAST zone diameters were compared with the sDD zone diameters. The categorical agreement based on the readable zone diameters for the 4th, 8th, and 20th h was K.pneumoniae (99.7 %,99.7 %,99.7 %), E.coli (99.4 %,99.6 %,99.7 %), A.baumannii (98.7 %,98.7 %,98.7 %), P.aeruginosa (100 %,99.3 %,100 %), S. aureus (100 %,100 %,100 %), and Enterococcus spp. (100 %,100 %,100 %). The minor error(mE), major error(ME), and very major error(VME) results obtained in the whole study were determined as 0.9, 0, and 1.3 for 4 h; 1.4, 0, and 1.3 for 8 h; 0.6, 0, and 1.3 for 20 h. The EUCAST RAST study can be performed from positive bottles in the Autobio BC blood culture system, resulting in reliable outcomes. To report earlier antibiotic susceptibility test results, laboratories using Autobio BC can combine RAST with quality control studies.
血流感染的早期诊断和有效治疗可显著改善预后。欧洲抗菌药物敏感性试验委员会(EUCAST)基于纸片扩散法开发了快速抗菌药物敏感性试验(RAST)。在本研究中,我们将Autobio BC(郑州安图生物工程股份有限公司,中国)血培养系统中阳性血培养物的RAST研究数据与使用标准纸片扩散法获得的数据进行了比较。共收集了234份加标血培养样本(肺炎克雷伯菌[n = 50]、大肠埃希菌[n = 50]、鲍曼不动杆菌[n = 20]、铜绿假单胞菌[n = 13]、金黄色葡萄球菌[n = 51]和肠球菌属[n = 50])。对阳性培养瓶进行RAST试验,并在4、8和20小时测量结果。进行标准纸片扩散试验(sDD),并从血培养瓶中获得的亚培养样本测量抑菌圈直径。将RAST抑菌圈直径与sDD抑菌圈直径进行比较。基于第4、8和20小时可读抑菌圈直径的分类一致性为:肺炎克雷伯菌(99.7%,99.7%,99.7%)、大肠埃希菌(99.4%,99.6%,99.7%)、鲍曼不动杆菌(98.7%,98.7%,98.7%)、铜绿假单胞菌(100%,99.3%,100%)、金黄色葡萄球菌(100%,100%,100%)和肠球菌属(100%,100%,100%)。整个研究中获得的次要误差(mE)、主要误差(ME)和极主要误差(VME)结果在4小时时分别确定为0.9、0和1.3;8小时时为1.4、0和1.3;20小时时为0.6、0和1.3。EUCAST的RAST研究可在Autobio BC血培养系统的阳性培养瓶中进行,结果可靠。为了更早报告抗生素敏感性试验结果,使用Autobio BC的实验室可将RAST与质量控制研究相结合。