Budde Ricardo P J, Faure Marguerite E, Abbara Suhny, Alkadhi Hatem, Cremer Paul C, Feuchtner Gudrun M, Gonzales Holly M, Kiefer Todd L, Leipsic Jonathan, Nieman Koen, Revels Jonathan, Wang Dee Dee, Williamson Eric, Wyler von Ballmoos Moritz C, Zwischenberger Brittany A, Salgado Rodrigo
Department of Radiology & Nuclear Medicine, Erasmus Medical Center, Rotterdam, the Netherlands.
Department of Radiology & Nuclear Medicine, Erasmus Medical Center, Rotterdam, the Netherlands.
J Cardiovasc Comput Tomogr. 2025 Jul-Aug;19(4):366-386. doi: 10.1016/j.jcct.2025.04.007. Epub 2025 Jun 17.
Prosthetic heart valve (PHV) dysfunction is increasingly seen due to the increase in the number of PHV that are being implanted worldwide. Cardiac CT imaging has emerged as a valuable tool to assess PHVs and determine the cause of dysfunction. This consensus document first summarizes the available techniques for PHV assessment. Then the use of CT in PHV (dys)function assessment is discussed in detail including consensus statements for correct indications and patient selection for CT assessment of PHVs, image acquisition, reconstruction and measurement protocols and how to interpret and report the CT findings for specific types of PHV dysfunction.
由于全球范围内植入的人工心脏瓣膜(PHV)数量增加,PHV功能障碍越来越常见。心脏CT成像已成为评估PHV并确定功能障碍原因的重要工具。本共识文件首先总结了现有的PHV评估技术。然后详细讨论了CT在PHV(功能)障碍评估中的应用,包括PHV CT评估的正确适应症和患者选择、图像采集、重建和测量方案的共识声明,以及如何解释和报告特定类型PHV功能障碍的CT结果。