Suppr超能文献

超声测量头臀距的标准化:一项比较有会阴压迫和无会阴压迫技术的初步研究。

Standardization of the sonographic measurement of the head to perineum distance: A pilot study comparing techniques with and without perineal compression.

作者信息

Ramirez Zegarra Ruben, Cimino Giulia, Bonetti Monica, Melito Chiara, Bontempo Priscilla, Conforti Federica, Barreñada Lasai, Zupi Errico, Dall'asta Andrea, Ghi Tullio

机构信息

Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy; Division of Clinical Epidemiology, Department of Clinical Research, University Hospital Basel, University of Basel, Basel, Switzerland.

Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy; Department of Molecular and Developmental Medicine, Obstetrics and Gynecological Clinic, University of Siena, Siena, Italy.

出版信息

Eur J Obstet Gynecol Reprod Biol. 2025 Aug;312:114520. doi: 10.1016/j.ejogrb.2025.114520. Epub 2025 Jun 13.

Abstract

OBJECTIVES

To evaluate the relationship between head-to-perineum distance (HPD) measurements obtained with (compressed HPD) and without (uncompressed HPD) compression of the perineum, and to establish a conversion rule between these measurements. Additionally, we investigated whether the body mass index (BMI) of the participant impacted these two types of measurements.

STUDY DESIGN

Prospective cohort study conducted at the University Hospital of Parma, Italy, involving a non-consecutive cohort of singleton pregnancies with cephalic presenting fetus at 37 weeks or more. HPD was sonographically assessed using two different techniques: 1) applying compression on the soft tissues of the perineum (compressed HPD), or 2) without compressing the perineum (uncompressed HPD). The main outcome was the development of a conversion model between both HPD measurements. The secondary outcome was the relationship between BMI and HPD measurements. We identified the best regression model by systematically exploring polynomial regression (orders 1 and 2) adjusted with restricted cubic splines or fractional polynomials, applying different variable transformations.

RESULTS

From July 2023 to June 2024, we included 109 participants, of which 78.9 % were nulliparous with a mean age of 32.4 ± 5.2 years, and a body mass index at inclusion of 26.7 ± 4.2. The best model was a log-log transformation of both HPD variables, fitted with a 2nd-degree polynomial and restricted cubic splines with 2 knots at the 33rd and 66th percentiles. The interaction between BMI and compressed HPD did not significantly alter the model (ΔR = 0.001 and ΔF = -19.9, p = 0.25). Subsequently, we constructed a conversion table that provides estimated uncompressed HPD values (in mm) for a range of compressed HPD measurements (in mm), using the best regression model.

CONCLUSION

In this pilot study, we developed a regression model using restricted cubic splines to convert between both HPD measurements. BMI did not seem to significantly influence the relationship between the two HPD measurements, suggesting the model's applicability across different body compositions. Further validation of our model in a larger cohort is needed before clinical implementation.

摘要

目的

评估会阴压缩时(压缩性头-会阴距离,compressed HPD)和未压缩时(未压缩性头-会阴距离,uncompressed HPD)所测得的头-会阴距离(HPD)之间的关系,并建立这两种测量值之间的转换规则。此外,我们还研究了参与者的体重指数(BMI)是否会影响这两种测量值。

研究设计

在意大利帕尔马大学医院进行的前瞻性队列研究,纳入了非连续队列的单胎妊娠,胎儿为头先露且孕周在37周及以上。使用两种不同技术通过超声评估HPD:1)对会阴软组织施加压迫(压缩性HPD),或2)不压迫会阴(未压缩性HPD)。主要结果是建立两种HPD测量值之间的转换模型。次要结果是BMI与HPD测量值之间的关系。我们通过系统探索用受限立方样条或分数多项式调整的多项式回归(1阶和2阶),应用不同的变量变换,确定了最佳回归模型。

结果

从2023年7月到2024年6月,我们纳入了109名参与者,其中78.9%为初产妇,平均年龄为32.4±5.2岁,纳入时体重指数为26.7±4.2。最佳模型是对两个HPD变量进行对数-对数变换,拟合二阶多项式和在第33和66百分位数处有2个节点的受限立方样条。BMI与压缩性HPD之间的相互作用未显著改变模型(ΔR = 0.001,ΔF = -19.9,p = 0.25)。随后,我们使用最佳回归模型构建了一个转换表,该表提供了一系列压缩性HPD测量值(以毫米为单位)对应的估计未压缩性HPD值(以毫米为单位)。

结论

在这项初步研究中,我们使用受限立方样条开发了一个回归模型,用于在两种HPD测量值之间进行转换。BMI似乎并未显著影响两种HPD测量值之间的关系,这表明该模型适用于不同身体组成的人群。在临床应用之前,需要在更大的队列中对我们的模型进行进一步验证。