Saad Amr, Frings Andreas
Department of Ophthalmology, Heinrich Heine University, Moorenstraße 5, Duesseldorf, 40225, Germany.
Department of Ophthalmology, Stadtspital Zürich, Zurich, Switzerland.
Graefes Arch Clin Exp Ophthalmol. 2025 Jun 25. doi: 10.1007/s00417-025-06868-9.
To compare wavefront aberrometry (WA) refraction with subjective refraction (SR) before and after transepithelial photorefractive keratectomy (tPRK) or combined phototherapeutic keratectomy (PTK)-PRK.
In our monocentric retrospective study, we aimed to compare refraction measurements obtained using wavefront aberrometry (WA) with subjective refraction (SR) for 154 eyes that underwent PRK treatment. The eyes underwent either tPRK treatment with the Amaris750 excimer laser or combined PTK-PRK treatment with the MEL90 excimer laser. Preoperative spherical equivalent, age, and sex were matched between the two groups. Wavefront measurements were performed with Sirius in tPRK patients and with WASCA in PTK-PRK patients. Follow-up was 6 months postoperatively. We used Bland-Altman plots and intraclass coefficient (ICC) analysis to demonstrate the agreement of SR and WA refraction.
Preoperatively, there was a high agreement between WA and SR refraction in both treatment groups. However, postoperatively, there was almost no agreement between the two methods (ICC = 0). WA refraction provided more significant hyperopic refraction values postoperatively, while the agreement for cylinder values was lower compared to the sphere.
Our study shows that the choice of refraction measurement method should be carefully considered in PRK patients, particularly in the postoperative period and when using aberrometry systems. Further research with larger sample sizes is needed to fully investigate this topic.
比较经上皮准分子激光角膜切削术(tPRK)或联合光治疗性角膜切削术(PTK)-PRK术前和术后的波前像差验光(WA)与主观验光(SR)。
在我们的单中心回顾性研究中,我们旨在比较154只接受PRK治疗眼睛的波前像差验光(WA)和主观验光(SR)测量结果。这些眼睛接受了使用阿玛里斯750准分子激光的tPRK治疗或使用MEL90准分子激光的联合PTK-PRK治疗。两组之间术前球镜等效度、年龄和性别相匹配。tPRK患者使用Sirius进行波前测量,PTK-PRK患者使用WASCA进行波前测量。术后随访6个月。我们使用Bland-Altman图和组内相关系数(ICC)分析来证明SR和WA验光的一致性。
术前,两个治疗组的WA和SR验光之间具有高度一致性。然而,术后,两种方法之间几乎没有一致性(ICC = 0)。WA验光术后提供了更显著的远视验光值,而柱镜值的一致性与球镜相比更低。
我们的研究表明,PRK患者应仔细考虑验光测量方法的选择,特别是在术后阶段以及使用像差测量系统时。需要进行更大样本量的进一步研究以充分探讨该主题。