• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Evaluation of intermittent claudication using a treadmill with measurement of systolic pressure at the ankle following exercise].

作者信息

Cristol R, Graisely B

出版信息

J Mal Vasc. 1985;10(2):101-7.

PMID:4056616
Abstract

Intermittent claudication (IC) and maximum walking distance (MWD) were studied in 173 patients and compared to post-stress Doppler claudicant ankle pressure (PSCAP) and to ankle index (PSCAI) recorded 2 minutes after exercise. Self-evaluation of MWD by the patient was inaccurate in 60% of cases. The treadmill testing (at 12% of rate and 2 miles/hour) exhibited a clinically overt IC in 93 cases with MWD of 166 m +/- 76, a PSCAP of 24 mm Hg +/- 24 and a PSCAI of 0.17 +/- 0.17. A clinically questionable IC occurred in 50 cases with significantly higher values (p less than 0.001) for MWD (278 m +/- 75) PSCAP (52 mm Hg +/- 24) and PSCAI (0.34 +/- 0.16). In 30 cases without IC after 400 m on treadmill, the PSCAP (81 mm HG +/- 26) and the PSCAI (0.57 +/- 0.18) were significantly (p less than 0.001) higher than in IC groups and related to milder iliofemoral stenosis. Overall reproducibility of MWD (mean = 190 m +/- 90) with 2 or 3 repeated measures in 75 cases, was 10.8% +/- 8.6 with large individual variations. Overall reproducibility of PSCAP after standardized treadmill testing in 42 cases was 6.5 +/- 5.3 (range of CV = 0 to 16%). A variation of PSCAP of more than 15 mm Hg is considered significant at level 0.01. It is concluded that overt IC with foot pallor and PSACP at 40 mm Hg or less reflects actual and reproducible MWD (especially below 300 m).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
[Evaluation of intermittent claudication using a treadmill with measurement of systolic pressure at the ankle following exercise].
J Mal Vasc. 1985;10(2):101-7.
2
Measurement of walking distance and speed in patients with peripheral arterial disease: a novel method using a global positioning system.外周动脉疾病患者步行距离和速度的测量:一种使用全球定位系统的新方法。
Circulation. 2008 Feb 19;117(7):897-904. doi: 10.1161/CIRCULATIONAHA.107.725994. Epub 2008 Feb 4.
3
Progressive vs single-stage treadmill tests for evaluation of claudication.用于评估间歇性跛行的渐进式与单阶段跑步机测试
Med Sci Sports Exerc. 1991 Apr;23(4):402-8.
4
A preliminary study on the effects of exercising to maximum walking distance on platelet and endothelial function in patients with intermittent claudication.运动至最大步行距离对间歇性跛行患者血小板及内皮功能影响的初步研究
Eur J Vasc Endovasc Surg. 2006 Mar;31(3):266-73. doi: 10.1016/j.ejvs.2005.10.011. Epub 2005 Dec 19.
5
The relationship of walking distances estimated by the patient, on the corridor and on a treadmill, and the Walking Impairment Questionnaire in intermittent claudication.患者在走廊和跑步机上自行估计的行走距离与间歇性跛行行走障碍问卷的关系。
J Vasc Surg. 2013 Mar;57(3):720-727.e1. doi: 10.1016/j.jvs.2012.09.044. Epub 2013 Jan 11.
6
A single treadmill exercise test does not accurately quantitate claudication.单次跑步机运动试验不能准确量化跛行。
Can J Surg. 1987 Nov;30(6):446-8.
7
Supervised exercise training for intermittent claudication: lasting benefit at three years.间歇性跛行的监督性运动训练:三年持续获益
Eur J Vasc Endovasc Surg. 2007 Sep;34(3):322-6. doi: 10.1016/j.ejvs.2007.04.014. Epub 2007 Jun 22.
8
Functional assessment at the buttock level of the effect of aortobifemoral bypass surgery.腹主动脉双股动脉搭桥手术效果在臀部水平的功能评估。
Ann Surg. 2008 May;247(5):869-76. doi: 10.1097/SLA.0b013e31816bcd75.
9
Plantar flexion as an alternative to treadmill exercise for evaluating patients with intermittent claudication.跖屈作为评估间歇性跛行患者的一种替代跑步机运动的方法。
Eur J Vasc Endovasc Surg. 2007 Mar;33(3):325-9. doi: 10.1016/j.ejvs.2006.10.012. Epub 2006 Nov 28.
10
The role of pedometers in the assessment of intermittent claudication.计步器在间歇性跛行评估中的作用。
Eur J Vasc Endovasc Surg. 2002 Apr;23(4):317-20. doi: 10.1053/ejvs.2001.1581.