Abstract

To address the challenges related to IOL explantation and associated complications, we have developed an innovative tip that utilizes the ultrasonic power of phaco machine for efficient IOL cutting. The tip can be easily screws into phaco machine, while the other end is forked with sharp inner margins. This cutter is complemented by the ergonomically designed microforceps which are inserted through a side port to grasp the lens securely during cutting.

摘要

为应对与人工晶状体取出及相关并发症有关的挑战,我们开发了一种创新型尖端,它利用超声乳化仪的超声能量来高效切割人工晶状体。该尖端可轻松拧入超声乳化仪,另一端呈叉状,内部边缘锋利。这种切割器辅以符合人体工程学设计的微型镊子,微型镊子通过侧切口插入,以便在切割过程中牢固地抓取晶状体。