植入听觉假体受试者的当前前庭状态。

Present vestibular status of subjects implanted with auditory prostheses.

作者信息

Black F O

出版信息

Ann Otol Rhinol Laryngol Suppl. 1977 May-Jun;86(3 Pt 3 Suppl 38):49-56. doi: 10.1177/00034894770860s306.

Abstract

Electronstagmographic studies were performed on all 13 patients with the caloric stimulus series, omitted in two subjects with external otitis. Eleven of the 13 subjects exhibited normal eye movement screening tests. Of the remaining nine subjects who could be evaluated, all demonstrated markedly reduced or absent caloric-induced nystagmus responses. These results confirmed preoperative vestibular test findings performed by implant surgery teams and indicated that the vestibular systems of the patients were severly damaged.

摘要

对所有13例患者进行了眼震电图检查,采用冷热刺激系列,2例患有外耳炎的受试者未进行该检查。13例受试者中有11例眼动筛查试验正常。在其余9例可评估的受试者中,所有受试者冷热诱发的眼震反应均显著降低或消失。这些结果证实了植入手术团队术前进行的前庭测试结果,表明患者的前庭系统严重受损。