Yu Jiayun, Sun Yiting, Sun Hongjing, Zhuoruo Xirenayi, Cai Jiangxiong, Jin Xiuming
Zhejiang University, Eye Center of Second Affiliated Hospital, School of Medicine, Hangzhou, China.
Zhejiang Provincial Key Laboratory of Ophthalmology, Zhejiang Provincial Clinical Research Center for Eye Diseases, Hangzhou, China.
Sci Rep. 2025 Jul 1;15(1):21003. doi: 10.1038/s41598-025-06328-8.
This study aimed to assess whether Relumino mode TV could assist amblyopic patients using video terminals. This mode utilizes real-time image processing techniques to enhance visual effects. We recruited 38 participants with anisometropic amblyopia, all literate and cognitively capable. The Modulation Transfer Function (MTF) of the normal and Relumino modes was measured to evaluate the relationship between spatial frequency variations and visual effects. All participants underwent tests for visual acuity, reading performance (reading speed and accuracy), and viewing three 5-min videos in both modes. Afterward, they completed a Visual Function Evaluation Questionnaire. A total of 38 volunteers (mean age, 17.0 ± 13.3 years) completed this study. The results indicated that in Relumino mode, the visual scores for static images and videos with lower MTF were 5.58 ± 1.66 (p = 0.038) and 5.33 ± 1.42 (p = 0.167), respectively, suggesting better visual function with Relumino mode, compared to the normal mode. However, no significant changes were found in the LogMAR mean values for amblyopic eyes (from 0.47 ± 0.26 to 0.49 ± 0.26, p = 0.237), reading speed (from 68.62 ± 59.13 to 74.39 ± 59.78, p = 0.209) or reading accuracy (from 0.96 ± 0.12 to 0.92 ± 0.17, p = 0.019) before and after using Relumino mode. There was no significant improvement in visual functions related to text on the screen. This study suggests that the Relumino mode enhances the visual experience for amblyopic patients when watching videos or images on the TV, especially compared to the normal mode.
本研究旨在评估Relumino模式电视是否能帮助弱视患者使用视频终端。该模式利用实时图像处理技术来增强视觉效果。我们招募了38名屈光参差性弱视参与者,他们均具备读写能力且认知功能正常。测量了正常模式和Relumino模式的调制传递函数(MTF),以评估空间频率变化与视觉效果之间的关系。所有参与者都进行了视力、阅读表现(阅读速度和准确性)测试,并在两种模式下观看了三个5分钟的视频。之后,他们完成了一份视觉功能评估问卷。共有38名志愿者(平均年龄17.0±13.3岁)完成了本研究。结果表明,在Relumino模式下,MTF较低的静态图像和视频的视觉评分分别为5.58±1.66(p = 0.038)和5.33±1.42(p = 0.167),这表明与正常模式相比,Relumino模式具有更好的视觉功能。然而,弱视眼的LogMAR平均值(从0.47±0.26变为0.49±0.26,p = 0.237)、阅读速度(从68.62±59.13变为74.39±59.78,p = 0.209)或阅读准确性(从0.96±0.12变为0.92±0.17,p = 0.019)在使用Relumino模式前后均未发现显著变化。与屏幕上的文本相关的视觉功能没有显著改善。本研究表明,Relumino模式在弱视患者观看电视上的视频或图像时能增强视觉体验,尤其是与正常模式相比。