Aryannejad Majid, Ghazi Oskouei Hooman, Mazhari Marzieh, Moradinezhad Mehrnaz
School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
Department of Orthodontics, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
BMC Oral Health. 2025 Jul 2;25(1):1021. doi: 10.1186/s12903-025-06367-7.
Both orthodontists and patients frequently express concerns about the discolorations of elastomeric ligatures. It is important to know which toothpastes or brands or other factors can severely discolor elastic ligatures. Despite the clinical importance of this matter, the literature in this regard is very scarce (only 3 studies) with contradicting results. Therefore, the aim of this study was to evaluate the impact of whitening and regular toothpastes on the color stability of clear elastomeric ligatures from different brands, applied to different incisors.
In this hierarchical 6-arm split-mouth double-blind randomized clinical trial, 264 ligatures were applied to orthodontic brackets bonded to bilateral mandibular central and lateral incisors in 66 patients: The sample was randomized twice: Once it was randomly divided into three groups of toothpastes (n = 66 patients): Regular Crest, Advance White Arm & Hammer Whitening, and Extra Whitening Crest. The next phase was split-mouth: In each patient, one side of the mouth was randomly assigned to Ortho Organizer brand while the other side was assigned to Ortho Technology ligatures. In the baseline, the ligatures were evaluated using the CIE Lab color system. After four weeks, the ligatures were re-evaluated using the CIE Lab* color system. The extents of changes in color parameters L, A, B, and E were analyzed using 3-way repeated-measures ANOVA. Other statistical analyses were also conducted using repeated-measures ANOVA, Pearson correlation coefficient, and independent-samples t-test (α = 0.05).
The overall color stability of elastic ligatures was not influenced by the toothpastes in use (P = 0.649 for ∆E, P values ranging between 0.669 and 0.989 for other parameters) or the type of incisor on which the ligature was mounted (P = 0.656 for ∆E, P values ranging between 0.006 and 0.647 for other parameters). The discolorations of elastic ligatures were significantly different between the two ligature brands (P = 0.000 for ∆E, P values = 0.000 for other parameters). Ortho Organizer showed a higher color stability than Ortho Technology. Both ligature brands showed a level of discoloration deemed clinically unacceptable (E > 3.3), regardless of the toothpaste used. Discolorations were mostly due to severe changes in ∆B parameter (yellowness) compared to ∆L or ∆A (P = 0.000).
Although the type of toothpaste has no significant impact on the color stability of elastomeric ligatures, the brand of ligatures individually plays a significant role in this regard.
The study was prospectively registered with the Iranian Registry of Clinical Trials on March 28, 2022 (IRCT Code: IRCT20220315054292N1) before beginning the study.
正畸医生和患者经常对弹性结扎圈变色表示担忧。了解哪些牙膏、品牌或其他因素会严重使弹性结扎圈变色很重要。尽管此事具有临床重要性,但这方面的文献非常稀少(仅有3项研究)且结果相互矛盾。因此,本研究的目的是评估美白牙膏和普通牙膏对不同品牌的透明弹性结扎圈颜色稳定性的影响,这些结扎圈应用于不同的切牙。
在这项分层6臂分口双盲随机临床试验中,将264个结扎圈应用于66例患者双侧下颌中切牙和侧切牙上粘结的正畸托槽:样本进行了两次随机分组:首先随机分为三组牙膏组(n = 66例患者):普通佳洁士牙膏、Advance White Arm & Hammer美白牙膏和Extra Whitening Crest美白牙膏。下一阶段是分口:在每位患者中,口腔一侧随机分配使用Ortho Organizer品牌结扎圈,另一侧分配使用Ortho Technology品牌结扎圈。在基线时,使用CIE Lab颜色系统对结扎圈进行评估。四周后,再次使用CIE Lab*颜色系统对结扎圈进行评估。使用三因素重复测量方差分析分析颜色参数L、A、B和E的变化程度。还使用重复测量方差分析、Pearson相关系数和独立样本t检验进行了其他统计分析(α = 0.05)。
使用的牙膏(∆E的P = 0.649,其他参数的P值在0.669至0.989之间)或结扎圈所安装的切牙类型(∆E的P = 0.656,其他参数的P值在0.006至0.647之间)对弹性结扎圈的整体颜色稳定性没有影响。两种结扎圈品牌之间弹性结扎圈的变色存在显著差异(∆E的P = 0.000,其他参数的P值 = 0.000)。Ortho Organizer品牌显示出比Ortho Technology品牌更高的颜色稳定性。无论使用何种牙膏,两种结扎圈品牌都显示出临床不可接受的变色程度(E > 3.3)。与∆L或∆A相比,变色主要是由于∆B参数(黄度)的严重变化(P = 0.000)。
尽管牙膏类型对弹性结扎圈的颜色稳定性没有显著影响,但结扎圈品牌在这方面各自起着重要作用。
该研究在2022年3月28日在伊朗临床试验注册中心进行了前瞻性注册(IRCT代码:IRCT20220315054292N1),在研究开始之前。