A simple, fast, and highly convenient autoanalyzer is proposed and demonstrated for the colorimetric measurement of nitrite, phosphate, and silicate in natural waters. The system employs individual micro peristaltic pumps controlled by integrated electric relay modules, allowing the main flow to be regulated in a stepwise manner. Activation is initiated by a single "start" button, which triggers a series of preprogramed actions, including sample loading, reagent mixing, refluxing of residual liquid, pausing for complete color development, and flushing the system with distilled water to reset the baseline to zero. Each measurement cycle is completed within 100 s with mild online heating. Real-time signals are captured via dynamic data exchange (DDE) and transferred to an Excel worksheet for instant calculation and display. Three systems are constructed and demonstrated for the determination of nitrite, phosphate, and silicate. Results indicate that over 99% completeness of the chemical reaction has been achieved with a precision better than ± 0.5% R.S.D. As each system is dedicated to a specific parameter, simplifying maintenance and minimizing troubleshooting, the system is highly convenient for use aboard research vessels or in busy laboratories, catering to users who need immediate measurements in either the "one-touch-one-sample" or "automatic-repeating" mode on a self-service basis.
本文提出并展示了一种简单、快速且极为便捷的自动分析仪,用于比色法测定天然水中的亚硝酸盐、磷酸盐和硅酸盐。该系统采用由集成继电器模块控制的单个微型蠕动泵,可对主流进行逐步调节。通过单个“开始”按钮启动,该按钮触发一系列预编程操作,包括样品加载、试剂混合、残留液体回流、暂停直至显色完全,以及用蒸馏水冲洗系统以将基线重置为零。在温和的在线加热条件下,每个测量周期在100秒内完成。通过动态数据交换(DDE)捕获实时信号,并传输到Excel工作表进行即时计算和显示。构建并展示了三个用于测定亚硝酸盐、磷酸盐和硅酸盐的系统。结果表明,化学反应的完成度超过99%,精密度优于±0.5%相对标准偏差(R.S.D.)。由于每个系统专门用于特定参数,简化了维护并最大限度减少了故障排查,该系统在研究船上或繁忙实验室中使用极为方便,适合那些需要以自助方式在“一键一样品”或“自动重复”模式下进行即时测量的用户。