Effects of Pupil Size on Functional Outcomes of a Simultaneous Vision Intraocular Lens.

作者信息

Davidova Petra, Kaiser Klemens P, Hemkeppler Eva, Böhm Myriam, Kohnen Thomas

出版信息

J Refract Surg. 2025 Jul;41(7):e645-e654. doi: 10.3928/1081597X-20250515-02. Epub 2025 Jul 1.

Abstract

PURPOSE

To evaluate the relationship between pupil size and subjective visual quality after implantation of a simultaneous vision intraocular lens (IOL).

METHODS

Patients after bilateral implantation of a trifocal, diffractive IOL were prospectively included. Three months postoperatively, subjective refraction, UDVA, and axis deviation were measured. Pupil size was obtained with an infrared-based pupillometer (PupilX; Albomed) in scotopic, mesopic, and photopic conditions. Subjective impairment with optical phenomena was surveyed in different lighting conditions.

RESULTS

Fifty-two patients (mean age: 68 years) were included; 54 eyes received non-toric IOLs and 50 eyes received toric IOLs. Preoperative spherical equivalent (SE) was -0.914 diopters (D) (range: -10.00 to +5.92 D) and SE and lens torus were 20.3 D (range: 9.00 to 32.00 D) and 1.65 D (range: 1.00 to 3.75 D), respectively. Three months postoperatively pupil size was 5.42 mm (range: 2.60 to 7.50 mm) in scotopic, 4.24 mm (range: 2.60 to 6.10 mm) in mesopic, and 3.38 mm (range: 1.20 to 5.60 mm) in photopic conditions, spherical manifest refractive error 0.14 D (range: -0.75 to 1.25 D), SE 0.034 D (range: -1.13 to +1.13 D), and UDVA 20/22.4 (range: 20/63 to 20/12.5). In low light conditions, halos correlated weakly with scotopic (r = 0.268, = .006) and mesopic ( = 0.298, = .002) pupil size and double-contour with scotopic pupil size ( = 0.234, = .018). Glare, starbursts, and blurred vision were not influenced in any condition. Further significant influential factors were postoperative spherical manifest refractive error ( = .014), SE ( = .007) and lens torus ( = .029) for halos and preoperative SE ( = .019), postoperative UDVA ( = .035), and lens SE ( = .023) for double-contour. In multiple regression analysis, lens torus, mesopic pupil size, preoperative SE, and postoperative UDVA remained significant.

CONCLUSIONS

Pupil size did not play a major role in disturbance with optical phenomena after implantation of a trifocal diffractive IOL. .

摘要

目的

评估植入同步视觉人工晶状体(IOL)后瞳孔大小与主观视觉质量之间的关系。

方法

前瞻性纳入双侧植入三焦点衍射IOL的患者。术后三个月,测量主观验光、最佳矫正远视力(UDVA)和轴位偏差。使用基于红外线的瞳孔计(PupilX;Albomed)在暗视、中间视觉和明视条件下测量瞳孔大小。在不同光照条件下调查光学现象引起的主观不适。

结果

纳入52例患者(平均年龄:68岁);54只眼植入非散光IOL,50只眼植入散光IOL。术前等效球镜度(SE)为-0.914屈光度(D)(范围:-10.00至+5.92 D),SE和晶状体散光分别为20.3 D(范围:9.00至32.00 D)和1.65 D(范围:1.00至3.75 D)。术后三个月,暗视条件下瞳孔大小为5.42 mm(范围:2.60至7.50 mm),中间视觉条件下为4.24 mm(范围:2.60至6.10 mm),明视条件下为3.38 mm(范围:1.20至5.60 mm),球镜显性屈光不正为0.14 D(范围:-0.75至1.25 D),SE为0.034 D(范围:-1.13至+1.13 D),UDVA为20/22.4(范围:20/63至20/12.5)。在低光条件下,光晕与暗视(r = 0.268,P = .006)和中间视觉(P = 0.298,P = .002)瞳孔大小弱相关,双轮廓与暗视瞳孔大小相关(P = 0.234,P = .018)。在任何条件下,眩光、星芒和视力模糊均未受影响。对于光晕,其他显著影响因素为术后球镜显性屈光不正(P = .014)、SE(P = .007)和晶状体散光(P = .029);对于双轮廓,为术前SE(P = .019)、术后UDVA(P = .035)和晶状体SE(P = .023)。在多元回归分析中,晶状体散光、中间视觉瞳孔大小、术前SE和术后UDVA仍然显著。

结论

在植入三焦点衍射IOL后,瞳孔大小在光学现象干扰中未起主要作用。