Suppr超能文献

高度近视眼植入衍射型三焦点人工晶状体的临床疗效评估:两年随访

Clinical efficacy evaluation of the implantation of a diffractive trifocal intraocular lens in high myopia eyes: Two-year follow-up.

作者信息

Liu Shasha, Wang Yao, Kang Tingting, Lv Wenhao, Ma Ruonan, Yu Ying, Yin Lianrong

机构信息

Department of Refractive Surgery, Eye Hospital of China Academy of Chinese Medical Sciences, Shijingshan District, Beijing, China.

出版信息

Indian J Ophthalmol. 2025 Jan 1;73(1):95-101. doi: 10.4103/IJO.IJO_146_24. Epub 2024 Sep 10.

Abstract

PURPOSE

To evaluate the long-term subjective and objective visual quality after implantation of a diffractive trifocal intraocular lens (IOL) in high myopic eyes.

METHODS

A total of 53 eyes from 38 patients with high myopia who underwent phacoemulsification and trifocal IOL implantation were investigated. The visual acuity, contrast sensitivity, diopter, defocus curve, and objective visual quality at 1 month, 3 months, 1 year, and 2 years after surgery, as well as the satisfaction questionnaire and VF-14 scale, were statistically analyzed.

RESULTS

The average age was 53.14 ± 4.70 years. The average preoperative spherical equivalent was -10.77 ± 3.98 D. Two years after surgery, 94.3% of the patients achieved an uncorrected distance visual acuity of 0.1 (LogMAR), and 84.9% and 94.3% of the patients had SE within ±0.50 D and ±1.0 D, respectively. The defocus curve was smooth and at a high value within the range of 0 D to -2.50 D. In CS or objective visual quality, there was no significant difference at 3 months, 1 year, and 2 years after operation (all P > 0.05). The rate of spectacle independence was 100%. The proportion of patients with moderate or severe glare and halo was 10.5% and 13.2%, respectively. Furthermore, 23.7%, 26.3%, and 18.4% of the patients had difficulties in reading small font, doing delicate tasks, and driving or riding at night, respectively.

CONCLUSION

The diffractive trifocal IOL implantation provided good distance, intermediate, and near uncorrected visual acuity for patients with cataracts and high myopia. It was safe, effective, predictable, and stable. It provided long-term good visual quality after surgery, with high spectacle independence and high patient satisfaction.

摘要

目的

评估高度近视眼中植入衍射三焦点人工晶状体(IOL)后的长期主观和客观视觉质量。

方法

对38例接受白内障超声乳化和三焦点IOL植入术的高度近视患者的53只眼进行研究。对术后1个月、3个月、1年和2年时的视力、对比敏感度、屈光度、散焦曲线和客观视觉质量,以及满意度问卷和VF - 14量表进行统计分析。

结果

平均年龄为53.14±4.70岁。术前平均等效球镜度为-10.77±3.98D。术后两年,94.3%的患者裸眼远视力达到0.1(LogMAR),84.9%和94.3%的患者的等效球镜度分别在±0.50D和±1.0D范围内。散焦曲线平滑,在0D至-2.50D范围内处于较高值。在对比敏感度或客观视觉质量方面,术后3个月、1年和2年时无显著差异(所有P>0.05)。脱镜率为100%。中度或重度眩光和光晕的患者比例分别为10.5%和13.2%。此外,分别有23.7%、26.3%和18.4%的患者在阅读小字体、进行精细任务以及夜间驾驶或骑行方面存在困难。

结论

衍射三焦点IOL植入为白内障合并高度近视患者提供了良好的远、中、近裸眼视力。它安全、有效、可预测且稳定。术后提供了长期良好的视觉质量,脱镜率高,患者满意度高。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d55a/11831943/678a470a89d5/IJO-73-95-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验