A previously undescribed type of fracture of the neck of femur occurred following intertrochanteric fracture fixation with a McLaughlin nail plate in an 80-year-old woman. This complication was probably caused by prolonged non-weight-bearing and inadequate fixation. The complication possibly could have been avoided by use of a dynamic hip screw and early weight-bearing.
一名80岁女性在使用麦克劳克林钉板进行股骨转子间骨折固定后,出现了一种此前未被描述过的股骨颈骨折类型。这种并发症可能是由于长期不负重和固定不充分所致。使用动力髋螺钉并早期负重或许可以避免这种并发症。