OBJECTIVE

Clinical trials of the photovoltaic subretinal prosthesis PRIMA demonstrated feasibility of prosthetic central vision with resolution matching its 100µm pixel size. To improve prosthetic acuity further, pixel size should be decreased. However, there are multiple challenges, one of which is related to accommodating a compact shunt resistor within each pixel that discharges the electrodes between stimulation pulses and helps increase the contrast of the electric field pattern. Unfortunately, standard materials used in integrated circuit resistors do not match the resistivity required for small photovoltaic pixels. Therefore, we used a novel material - doped amorphous silicon (a-Si) and integrated it into photovoltaic arrays with pixel sizes down to 20µm.

APPROACH

To fit within a few µm area of the pixels and provide resistance in the MΩ range, the material should have sheet resistance of a few hundred kΩ/sq, which translates to resistivity of a few Ω*cm. The a-Si layer was deposited by low-pressure chemical vapor deposition (LPCVD) and its resistivity was adjusted by PH doping before encapsulating the resistors between SiO and SiC for stability in-vivo.

MAIN RESULTS

High-resolution retinal implants with integrated shunt resistors were fabricated with values ranging from 0.75 to 4 MΩ on top of the photovoltaic pixels of 55, 40, 30 and 20 µm in size. Photoresponsivity with all pixel sizes was approximately 0.53 A/W, as high as in the arrays with no shunt resistor. The shunts shortened electrodes discharge time, with the average electric potential in electrolyte decreasing by only 21-31% when repetition rate increased from 2 to 30 Hz, as opposed to a 54-55% decrease without a shunt. Similarly, contrast of a Landolt C pattern increased from 16-22% with no shunt to 22-34% with a shunt. Further improvement in contrast is expected with pillar electrodes and local returns within each pixel.

SIGNIFICANCE

Miniature shunt resistors in a MOhm range can be fabricated from doped a-Si in a process compatible with manufacturing of photovoltaic arrays. The shunt resistors improved current injection and spatial contrast at video frame rates, without compromising the photoresponsivity. These advances are critical for scaling pixel sizes below 100 µm to improve visual acuity of prosthetic vision.

摘要

目的

光伏视网膜下假体PRIMA的临床试验证明了假体中央视觉的可行性,其分辨率与其100μm像素尺寸相匹配。为了进一步提高假体视力,应减小像素尺寸。然而,存在多个挑战,其中之一与在每个像素内安置一个紧凑的分流电阻器有关,该电阻器在刺激脉冲之间使电极放电,并有助于增加电场模式的对比度。不幸的是,集成电路电阻器中使用的标准材料与小型光伏像素所需的电阻率不匹配。因此,我们使用了一种新型材料——掺杂非晶硅(a-Si),并将其集成到像素尺寸低至20μm的光伏阵列中。

方法

为了适应像素的几微米面积并提供兆欧范围内的电阻,该材料的薄层电阻应为几百千欧/平方,这相当于电阻率为几欧姆·厘米。通过低压化学气相沉积(LPCVD)沉积a-Si层,并在将电阻器封装在SiO和SiC之间以实现体内稳定性之前,通过PH掺杂来调整其电阻率。

主要结果

在尺寸为55、40、30和20μm的光伏像素顶部制造了集成分流电阻器的高分辨率视网膜植入物,其阻值范围为0.75至4兆欧。所有像素尺寸的光响应度约为0.53 A/W,与没有分流电阻器的阵列一样高。分流器缩短了电极放电时间,当重复频率从2 Hz增加到30 Hz时,电解液中的平均电势仅降低21%-31%,而没有分流器时降低54%-55%。同样,朗道C图案的对比度从没有分流器时的16%-22%增加到有分流器时的22%-34%。预计采用柱状电极和每个像素内的局部回路可进一步提高对比度。

意义

可以通过掺杂a-Si在与光伏阵列制造兼容的工艺中制造兆欧范围内的微型分流电阻器。分流电阻器在视频帧率下改善了电流注入和空间对比度,而不影响光响应度。这些进展对于将像素尺寸缩小到100μm以下以提高假体视觉的视力至关重要。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2754/12248045/d6dc064e96a8/nihpp-2025.05.01.651774v1-f0001.jpg

相似文献

1
Amorphous silicon resistors enable smaller pixels in photovoltaic retinal prosthesis.
bioRxiv. 2025 May 7:2025.05.01.651774. doi: 10.1101/2025.05.01.651774.
3
Home treatment for mental health problems: a systematic review.
Health Technol Assess. 2001;5(15):1-139. doi: 10.3310/hta5150.
5
The effect of sample site and collection procedure on identification of SARS-CoV-2 infection.
Cochrane Database Syst Rev. 2024 Dec 16;12(12):CD014780. doi: 10.1002/14651858.CD014780.
6
Clinical symptoms, signs and tests for identification of impending and current water-loss dehydration in older people.
Cochrane Database Syst Rev. 2015 Apr 30;2015(4):CD009647. doi: 10.1002/14651858.CD009647.pub2.
7
Anterior Approach Total Ankle Arthroplasty with Patient-Specific Cut Guides.
JBJS Essent Surg Tech. 2025 Aug 15;15(3). doi: 10.2106/JBJS.ST.23.00027. eCollection 2025 Jul-Sep.
8
Surgical interventions for bilateral congenital cataract in children aged two years and under.
Cochrane Database Syst Rev. 2022 Sep 15;9(9):CD003171. doi: 10.1002/14651858.CD003171.pub3.
9
Interventions for infantile haemangiomas of the skin.
Cochrane Database Syst Rev. 2018 Apr 18;4(4):CD006545. doi: 10.1002/14651858.CD006545.pub3.

本文引用的文献

1
Accelerated Simulation of Multi-Electrode Arrays Using Sparse and Low-Rank Matrix Techniques.
IEEE Trans Biomed Eng. 2025 Aug;72(8):2321-2330. doi: 10.1109/TBME.2025.3541489.
2
Virtual human retina: Simulating neural signalling, degeneration, and responses to electrical stimulation.
Brain Stimul. 2025 Jan-Feb;18(1):144-163. doi: 10.1016/j.brs.2025.01.013. Epub 2025 Jan 17.
3
Prosthetic Visual Acuity with the PRIMA Subretinal Microchip in Patients with Atrophic Age-Related Macular Degeneration at 4 Years Follow-up.
Ophthalmol Sci. 2024 Mar 7;4(5):100510. doi: 10.1016/j.xops.2024.100510. eCollection 2024 Sep-Oct.
4
Three-dimensional electro-neural interfaces electroplated on subretinal prostheses.
J Neural Eng. 2024 Feb 23;21(1):016030. doi: 10.1088/1741-2552/ad2a37.
5
Photovoltaic implant simulator reveals resolution limits in subretinal prosthesis.
J Neural Eng. 2022 Sep 27;19(5). doi: 10.1088/1741-2552/ac8ed8.
6
Simultaneous perception of prosthetic and natural vision in AMD patients.
Nat Commun. 2022 Jan 26;13(1):513. doi: 10.1038/s41467-022-28125-x.
7
Vertical-junction photodiodes for smaller pixels in retinal prostheses.
J Neural Eng. 2021 Mar 16;18(3). doi: 10.1088/1741-2552/abe6b8.
8
Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration.
Ophthalmology. 2020 Aug;127(8):1097-1104. doi: 10.1016/j.ophtha.2020.02.024. Epub 2020 Feb 25.
9
Photovoltaic restoration of sight with high visual acuity.
Nat Med. 2015 May;21(5):476-82. doi: 10.1038/nm.3851. Epub 2015 Apr 27.
10
Photovoltaic Pixels for Neural Stimulation: Circuit Models and Performance.
IEEE Trans Biomed Circuits Syst. 2016 Feb;10(1):85-97. doi: 10.1109/TBCAS.2014.2376528. Epub 2015 Jan 23.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验