The effect of cavity depth on accuracy of intraoral scanners in intra-coronal restorations.

作者信息

Özden Yunus Emre, Doğu Kaya Bengü, Akbal Çağla, Yılmaz Atalı Pınar, Özkurt-Kayahan Zeynep

机构信息

Faculty of Dentistry Department of Prosthodontics, Yeditepe University, Istanbul, Türkiye.

Faculty of Dentistry, Department of Restorative Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Türkiye.

出版信息

BMC Oral Health. 2025 Jul 15;25(1):1169. doi: 10.1186/s12903-025-06556-4.

Abstract

PURPOSE

This study aimed to evaluate the effect of cavity depth on the accuracy of intraoral scanners (IOS) in intra-coronal restorations, focusing on trueness and precision as defined by International Organization for Standardization (ISO) 5725 standards.

MATERIALS AND METHODS

Three intra-coronal cavity designs with depths of 2.5 mm (n = 10), 5 mm (n = 10), and 7.5 mm (n = 10) were fabricated using 3-Dimentional (3D) printed tooth models. Scans (n = 30) were performed using the Trios 3 intraoral scanner, and accuracy was assessed by comparing scanned models to reference models. Trueness was measured as the root mean square (RMS) deviation, and precision was calculated from the interquartile range of average absolute distances. Statistical analyses were conducted using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni correction.

RESULTS

The accuracy of the IOS was significantly lower at a cavity depth of 7.5 mm compared to 5 mm and 2.5 mm (p < 0.05). RMS values were highest for the 7.5 mm depth, while the lowest precision was observed at this depth.

CONCLUSION

Cavity depth significantly affects the accuracy of IOS in intra-coronal restorations, with deeper cavities resulting in reduced accuracy. This highlights the importance of considering cavity depth when planning IOS workflows. This study shows that scanning accuracy decreases when the distance between the cavity floor and the cusp tip exceeds 5 mm. Elevating the cavity floor with direct methods may help improve scanning accuracy and enhance restoration outcomes.

摘要

目的

本研究旨在评估洞深度对冠内修复中口内扫描仪(IOS)准确性的影响,重点关注国际标准化组织(ISO)5725标准所定义的真实性和精密度。

材料与方法

使用三维(3D)打印牙齿模型制作三种洞深度分别为2.5毫米(n = 10)、5毫米(n = 10)和7.5毫米(n = 10)的冠内洞型。使用Trios 3口内扫描仪进行扫描(n = 30),通过将扫描模型与参考模型进行比较来评估准确性。真实性以均方根(RMS)偏差衡量,精密度根据平均绝对距离的四分位数间距计算。采用Kruskal-Wallis检验和经Bonferroni校正的Mann-Whitney U检验进行统计分析。

结果

与5毫米和2.5毫米相比,洞深度为7.5毫米时IOS的准确性显著降低(p < 0.05)。7.5毫米深度的RMS值最高,且该深度的精密度最低。

结论

洞深度显著影响IOS在冠内修复中的准确性,洞越深准确性越低。这突出了在规划IOS工作流程时考虑洞深度的重要性。本研究表明,当洞底与牙尖顶之间的距离超过5毫米时,扫描准确性会降低。采用直接方法抬高洞底可能有助于提高扫描准确性并改善修复效果。