Suppr超能文献

用于耳毒性监测项目的便携式听力测定法:一项范围综述

Mobile Audiometry for Use in Ototoxicity Monitoring Programs: A Scoping Review.

作者信息

Yim Pierre W C, Lim Zee Hui

机构信息

Duke-NUS Medical School, Singapore.

Department of Otolaryngology-Head & Neck Surgery, National University Hospital, Singapore.

出版信息

J Audiol Otol. 2025 Jul;29(3):166-180. doi: 10.7874/jao.2024.00815. Epub 2025 Jul 18.

Abstract

Ototoxicity monitoring programs (OMPs) for cisplatin-induced hearing loss have not been widely adopted in clinical practice for various reasons. Mobile audiometry (MA) offers cost and convenience advantages over conventional pure-tone audiometry (CA) and it is currently used in hearing screening. However, there is no consensus on whether MA can replace CA for measuring hearing thresholds in OMPs. This scoping review examines the challenges of OMPs and evaluates the diagnostic accuracy of MA for hearing thresholds. A comprehensive search was conducted in four databases from their inception to December 2024. Data on study characteristics, reported OMP challenges, MA specifications, test settings, and performance measures were extracted. Nine studies on OMP challenges were reviewed. Identified barriers were inconsistent referrals, resource constraints, low awareness of ototoxicity monitoring, and patient-related factors. Twenty-three studies reporting on three portable audiometers, and 14 app-based hearing tests were evaluated for the diagnostic accuracy of MA for hearing thresholds. Only two studies involved testing at extended high frequencies. Studies used measures including MA-CA threshold differences, sensitivity/specificity, and test-retest reliability. App-based MA represents an accessible and scalable solution to the resource constraints faced by OMPs. However, its diagnostic accuracy remains uncertain given the substantial methodological variability across studies. OMPs using MAs should consider clinically validated modalities.

摘要

顺铂所致听力损失的耳毒性监测项目(OMPs)因各种原因尚未在临床实践中广泛应用。与传统纯音听力测试(CA)相比,便携式听力测试(MA)具有成本低和便利性高的优势,目前已用于听力筛查。然而,对于在OMPs中MA是否可以替代CA来测量听力阈值,尚无共识。本综述探讨了OMPs面临的挑战,并评估了MA测量听力阈值的诊断准确性。对四个数据库从创建到2024年12月进行了全面检索。提取了关于研究特征、报告的OMP挑战、MA规格、测试设置和性能指标的数据。对九项关于OMP挑战的研究进行了综述。确定的障碍包括转诊不一致、资源限制、耳毒性监测意识低以及患者相关因素。对23项报告三种便携式听力计的研究和14项基于应用程序的听力测试进行了MA测量听力阈值诊断准确性的评估。只有两项研究涉及扩展高频测试。研究采用的测量方法包括MA与CA的阈值差异、灵敏度/特异性以及重测信度。基于应用程序的MA是解决OMPs面临的资源限制的一种可及且可扩展的解决方案。然而,鉴于各研究之间存在很大的方法学差异,其诊断准确性仍不确定。使用MA的OMPs应考虑经过临床验证的模式。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7090/12313441/5557df76b5ad/jao-2024-00815f1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验