Oliveira Gabriel S, Lima Ana Luiza, Gross Idejan P, Sa-Barreto Livia, Medeiros-Souza Patrícia, Gratieri Tais, Gelfuso Guilherme M, Cunha-Filho Marcilio
Laboratory of Food Drugs, and Cosmetics (LTMAC) University of Brasilia, Brasília, DF 70910-900, Brazil.
Faculty of Ceilandia, University of Brasilia (UnB), Brasília, DF 72220-900, Brazil.
ACS Omega. 2025 Jul 16;10(29):32384-32390. doi: 10.1021/acsomega.5c04686. eCollection 2025 Jul 29.
6-Mercaptopurine monohydrate (6-MP) is a drug often used in leukemia chemotherapy, but limited information is available about its cutaneous absorption, which raises concerns about occupational risks for healthcare professionals and caregivers. This study aimed to validate an analytical method using high-performance liquid chromatography (HPLC) for quantifying 6-MP in the skin, allowing the assessment of its cutaneous permeation. The validation of the proposed method demonstrated high selectivity against skin interferents, linearity ( = 0.999), precision, and sensitivity, with detection and quantification limits of 0.13 μg/mL and 0.39 μg/mL, respectively. The developed extraction procedure allowed reproducible drug recovery from the stratum corneum and remaining skin, minimizing the impact of enzymatic metabolism in these biological matrices. Using the developed method, a preliminary skin permeation test on porcine skin showed that 6-MP is retained mainly in the remaining skin, accumulating approximately 2% of the total dose applied within 30 min of testing, suggesting a high risk of dermal exposure. The results reinforce the need for preventive measures, such as personal protective equipment and strict handling protocols, to minimize drug exposure. Thus, the method described constitutes an essential tool in assessing the risk of topical contamination of 6-MP and can be used in long-term studies of skin permeation of this drug, contributing to the safety of health professionals, caregivers, and patients.
6-巯基嘌呤一水合物(6-MP)是一种常用于白血病化疗的药物,但关于其经皮肤吸收的信息有限,这引发了对医护人员和护理人员职业风险的担忧。本研究旨在验证一种使用高效液相色谱法(HPLC)定量皮肤中6-MP的分析方法,以便评估其经皮渗透情况。所提出方法的验证表明,该方法对皮肤干扰物具有高选择性、线性(r = 0.999)、精密度和灵敏度,检测限和定量限分别为0.13μg/mL和0.39μg/mL。所开发的提取程序能够从角质层和剩余皮肤中可重复回收药物,最大限度地减少这些生物基质中酶促代谢的影响。使用所开发的方法,对猪皮肤进行的初步经皮渗透试验表明,6-MP主要保留在剩余皮肤中,在测试30分钟内累积了约2%的给药总量,表明存在皮肤暴露的高风险。结果强化了采取预防措施的必要性,如个人防护设备和严格的操作规范,以尽量减少药物暴露。因此,所描述的方法是评估6-MP局部污染风险的重要工具,可用于该药物经皮渗透的长期研究,有助于医护人员、护理人员和患者的安全。