出版信息

Muscles. 2025 Feb 11;4(1):5. doi: 10.3390/muscles4010005.

Abstract

BACKGROUND

Algometry is a validated and reliable measurement tool, but there are still no reliable data for the different algometers used by different raters in the same participant.

OBJECTIVE

The aim of this study was to determine the intra-reliability of pressure pain thresholds (PPTs) measured using a digital algometer with and without a digital screen by different raters at the same time in a pain-free population.

METHODS

Participants were healthy adults. PPTs were assessed using two different algometers: a digital algometer with a digital screen for a feedback of the pressure curve rate (SpTech Digital Algometer); and a digital algometer without a screen (Wagner Instruments FDX-25, Greenwich, CT, USA). Four PPT points were used: upper trapezius, lumbar spine, extensor carpi ulnaris, and tibialis anterior. The Copenhagen Psychosocial Questionnaire II was used to assess burnout, stress, sleeping problems, depressive symptoms, somatic stress, and cognitive stress. The intraclass coefficients (ICCs) for intra-rater reliability was calculated using a two-way mixed effects model, single measurement type, and absolute agreement definition.

RESULTS

A total of 47 healthy participants with a mean age of 30.51 (11.35) years were included. The upper trapezius and extensor carpi ulnaris had the lowest PPT values, and the tibialis anterior had the highest PPT value. Females had the lowest PPT values when compared with males with < 0.05 in the upper trapezius and extensor carpi ulnaris regions. The intra-rater reliability ranged from good to excellent reliability, with the ICC values of rater 1 being higher when compared with rater 2. The PPT in tibialis anterior had the highest mean ICC scores.

CONCLUSIONS

The intra-rater reliability of PPTs measured by different digital algometers ranged from good to excellent reliability. The rater with more experience demonstrated higher reliability.

摘要

背景

压痛计是一种经过验证且可靠的测量工具,但对于同一受试者由不同评估者使用不同压痛计测量的数据,目前仍缺乏可靠资料。

目的

本研究旨在确定在无痛人群中,不同评估者同时使用带数字屏幕和不带数字屏幕的数字压痛计测量压力痛阈(PPT)的组内信度。

方法

参与者为健康成年人。使用两种不同的压痛计评估PPT:一种带数字屏幕可反馈压力曲线速率的数字压痛计(SpTech数字压痛计);另一种不带屏幕的数字压痛计(美国康涅狄格州格林威治市瓦格纳仪器公司的FDX - 25)。选取四个PPT测量点:斜方肌上部、腰椎、尺侧腕伸肌和胫骨前肌。采用哥本哈根心理社会问卷II评估倦怠、压力、睡眠问题、抑郁症状、躯体压力和认知压力。使用双向混合效应模型、单次测量类型和绝对一致性定义计算评估者内信度的组内相关系数(ICC)。

结果

共纳入47名健康参与者,平均年龄30.51(11.35)岁。斜方肌上部和尺侧腕伸肌的PPT值最低,胫骨前肌的PPT值最高。与男性相比,女性在斜方肌上部和尺侧腕伸肌区域的PPT值最低,差异有统计学意义(P<0.05)。评估者内信度从良好到优秀不等,评估者1的ICC值高于评估者2。胫骨前肌的PPT平均ICC得分最高。

结论

不同数字压痛计测量PPT的评估者内信度从良好到优秀不等。经验更丰富的评估者表现出更高的信度。