Abstract

Harnessing the potential of exhaled breath analysis is an emerging frontier in medical diagnostics, given breath is a rich source of volatile organic compound (VOC) biomarkers for different medical conditions. A current downfall in this field, however, is the lack of standardized and widely available methods for offline sampling of exhaled VOCs. Herein, strides are taken toward the standardization of breath sampling in Tedlar bags by exploring several factors that can impact VOC heterogeneity, including tubing material, chemical composition of collection bags, breath fractionation, exhalation volume, and transfer flow rate. After bag-based sampling standardization, performance was benchmarked using two offline breath sampling methods, Tedlar bags and the Respiration Collector for In Vitro Analysis (ReCIVA). Three volunteers from the laboratory with no known respiratory diseases donated ≥ n = 5 samples collected onto adsorption tubes via each method, which were analyzed through thermal desorption (TD) coupled with gas chromatography-mass spectrometry (GC-MS). Data processing revealed a set of 15 highly reliable on-breath VOCs detected across volunteers, and most analytes (except indole) demonstrated higher sensitivity using Tedlar bags. Calculating relative standard deviation (RSD) values showed Tedlar bags were also significantly more reproducible compared to the ReCIVA (p < 0.03). Agreement between the two methods was demonstrated through correlating VOC signals with high statistical significance (R = 0.70), indicating both devices are well situated for biomarker discovery applications.

摘要

鉴于呼出气体是不同医疗状况下挥发性有机化合物(VOC)生物标志物的丰富来源,利用呼出气体分析的潜力是医学诊断领域的一个新兴前沿。然而,该领域目前的一个缺陷是缺乏用于呼出VOC离线采样的标准化且广泛可用的方法。在此,通过探索几个可能影响VOC异质性的因素,包括管材、收集袋的化学成分、呼气分级、呼气量和传输流速,朝着泰德拉袋中呼气采样的标准化迈出了步伐。在基于袋子的采样标准化之后,使用两种离线呼气采样方法(泰德拉袋和体外分析呼吸收集器(ReCIVA))对性能进行了基准测试。来自实验室的三名无已知呼吸系统疾病的志愿者通过每种方法捐赠了≥n = 5份收集到吸附管上的样本,这些样本通过热脱附(TD)结合气相色谱-质谱联用(GC-MS)进行分析。数据处理显示在志愿者中检测到一组15种高度可靠的呼出VOC,并且大多数分析物(除吲哚外)使用泰德拉袋时表现出更高的灵敏度。计算相对标准偏差(RSD)值表明,与ReCIVA相比,泰德拉袋的重现性也显著更高(p < 0.03)。通过将VOC信号进行具有高统计学意义的关联(R = 0.70),证明了两种方法之间的一致性,表明这两种设备都非常适合生物标志物发现应用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/db37/12402010/cb35543a45a5/216_2025_6025_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验