Meyerovitz M F, Levin D C, Harrington D P, Boxt L M, Bettmann M A, Garnic J D, Barry W H, Geller S C
Invest Radiol. 1985 Dec;20(9):945-9. doi: 10.1097/00004424-198512000-00010.
Biplane pulmonary cineangiograms utilizing a short cine pulse width and automatic brightness control were performed in 47 patients during normal respiration. The diagnostic quality of the arteriograms was categorized as good in 33 patients, fair in 12 patients, and poor in two patients. Of the 18 patients in whom pulmonary emboli were identified, cineangiography displayed certain diagnostic features to advantage, including motion of emboli in ten and respiratory scissoring of vessels overcoming vascular superimposition in three. Optimized pulmonary cineangiography is an acceptable alternative to serial film pulmonary angiography for the diagnosis of pulmonary embolism.
在47例患者正常呼吸过程中,利用短电影脉冲宽度和自动亮度控制进行了双平面肺血管造影电影检查。动脉造影的诊断质量在33例患者中被评为良好,12例患者中评为中等,2例患者中评为较差。在18例确诊为肺栓塞的患者中,血管造影电影检查显示出某些诊断优势特征,包括10例患者中栓子的移动以及3例患者中血管的呼吸性剪割,克服了血管重叠。优化后的肺血管造影电影检查是用于诊断肺栓塞的系列胶片肺血管造影的可接受替代方法。