Relationships between inspired oxygen concentration and venous admixture during nitrous oxide-oxygen-halothane anaesthesia.

作者信息

Kerr J H, Foex P, Pybus D A

出版信息

Br J Anaesth. 1985 Dec;57(12):1150-60. doi: 10.1093/bja/57.12.1150.

DOI:10.1093/bja/57.12.1150
PMID:4084426
Abstract

The inspired oxygen concentration (F/O2) was changed on 43 occasions at about 30-min intervals in 13 patients during artificial ventilation with mixtures of nitrous oxide (N2O), oxygen and halothane. Ventilator settings remained unchanged for each patient and at the end of each period, samples of arterial and central venous blood (and, in six patients, pulmonary arterial blood) and inspired and expired gases were collected. Oxygen tension was measured with a dedicated electrode shown to be unaffected by N2O. Venous admixture (Qva/Qt) was calculated at each F/O2. There was a highly significant correlation between the direction of change of F/O2 and that of Qva/Qt, irrespective of whether F/O2 increased or decreased. In 10 patients, there was a progressive increase in Qva/Qt as F/O2 increased above 40%, and in all patients Qva/Qt on nearly 100% oxygen was greater than that measured at the next lowest concentration (60-80%). These results are at variance with the pattern of behaviour predicted from the "critical Va/Q" theory and support the concept of an oxygen-dependent redistribution of perfusion.

摘要

相似文献

1
Relationships between inspired oxygen concentration and venous admixture during nitrous oxide-oxygen-halothane anaesthesia.
Br J Anaesth. 1985 Dec;57(12):1150-60. doi: 10.1093/bja/57.12.1150.
2
Endocrine stress response in jugular-vein cannulated rats upon multiple exposure to either diethyl-ether, halothane/O2/N2O or sham anaesthesia.多次暴露于乙醚、氟烷/氧气/一氧化二氮或假麻醉下的颈静脉插管大鼠的内分泌应激反应。
Lab Anim. 2002 Apr;36(2):105-14. doi: 10.1258/0023677021912316.
3
Persisting concentrating and second gas effects on oxygenation during N2O anaesthesia.笑气麻醉期间持续的浓缩效应和第二气体效应对氧合的影响。
Anaesthesia. 2006 Apr;61(4):322-9. doi: 10.1111/j.1365-2044.2006.04579.x.
4
Effects of nitrous oxide on respiration during halothane anaesthesia in the dog.
Br J Anaesth. 1988 Feb;60(2):207-15. doi: 10.1093/bja/60.2.207.
5
Arterial oxygen tension during nitrous oxide-oxygen-halothane anaesthesia in patients with cardiovascular and pulmonary disease.患有心血管和肺部疾病患者在氧化亚氮-氧气-氟烷麻醉期间的动脉血氧张力
Acta Anaesthesiol Scand. 1967;11(4):353-70. doi: 10.1111/j.1399-6576.1967.tb00400.x.
6
The effect of halothani-nitrous oxide anaesthesia and spontaneous ventilation on arterial blood oxygenation and physiological deadspace.
Anaesth Intensive Care. 1976 Feb;4(1):41-5. doi: 10.1177/0310057X7600400108.
7
Cerebral responses to the addition of nitrous oxide to halothane in man.人体中脑对在氟烷中添加氧化亚氮的反应。
Br J Anaesth. 1976 Oct;48(10):957-62. doi: 10.1093/bja/48.10.957.
8
Cardiovascular effects of induced hypercarbia during halothane-nitrous oxide anaesthesia.
Acta Chir Scand Suppl. 1976;472:127-32.
9
Ventilatory responses to carbon dioxide in children during nitrous oxide-halothane anaesthesia.氧化亚氮-氟烷麻醉期间儿童对二氧化碳的通气反应。
Br J Anaesth. 1985 Dec;57(12):1197-203. doi: 10.1093/bja/57.12.1197.
10
Anesthetic potency of nitrous oxide in young swine (Sus scrofa).
Am J Vet Res. 1985 Jan;46(1):58-60.

引用本文的文献

1
Summary of the scientific literature for pain and anxiety control in dentistry. Journal literature, January-December, 1985.牙科疼痛与焦虑控制的科学文献综述。期刊文献,1985年1月至12月。
Anesth Prog. 1986 Sep-Oct;33(5):268-77.
2
Stability of arterial to end-tidal carbon dioxide gradients during postoperative cardiorespiratory support.
Can J Anaesth. 1990 Jul;37(5):560-6. doi: 10.1007/BF03006326.