Suppr超能文献

癫痫患者中SPECT/CT、动态脑电图(AEEG)和三维动脉自旋标记(3D-pCASL)的比较。

Comparison of SPECT/CT, AEEG, and 3D-pCASL in people with epilepsy.

作者信息

Chen Rong, Zhang Qing, Li Yajun, Chen Jingyun, Wang Xu, Jin Yanzi, Li Fang, Chen Qiuyan, Li Mengyun

机构信息

Department of Neuroelectrophysiology, Cardiovascular and Cerebrovascular Disease Hospital Branch, General Hospital of Ningxia Medical University, Yinchuan, Ningxia, China.

Department of Neurology, General Hospital of Ningxia Medical University, Yinchuan, Ningxia, China.

出版信息

Front Neurol. 2025 Aug 20;16:1633993. doi: 10.3389/fneur.2025.1633993. eCollection 2025.

Abstract

OBJECTIVE

To analyze the clinical value of single-photon emission computed tomography (SPECT)/computed tomography (CT), ambulatory electroencephalogram (AEEG) and three-dimensional pseudo-continuous arterial spin labeling (3D-pCASL) in people with epilepsy (PWE).

METHODS

The study included 98 PWE who were treated in The General Hospital of Ningxia Medical University from December 2021 to September 2023. The positive detection rates and characteristics of SPECT/CT, AEEG and 3D-pCASL were compared. Additionally, the agreement between SPECT/CT, 3D-pCASL and AEEG-positive results was analyzed.

RESULTS

The positive detection rates for SPECT/CT, AEEG, and 3D-pCASL examinations were 77.55% (76/98), 62.24% (61/98), and 54.08% (53/98) respectively. SPECT/CT exhibited higher positive detection rates than AEEG (aOR = 1.165, 95%CI: 1.036-1.311, = 0.011) and 3D-pCASL (aOR = 1.265, 95%CI: 1.119-1.430, < 0.001), no significant difference was observed between AEEG and 3D-pCASL (aOR = 0.922, 95%CI: 0.810-1.048, = 0.213). In combined modalities, the positive detection rate of AEEG+SPECT/CT + 3D-pCASL (93.88%, 92/98) was higher than AEEG+3D-pCASL (79.59%, 78/98,  = 0.003), but showed no statistically significant difference compared to AEEG+SPECT/CT (88.78%, 87/98,  = 0.204). The proportions of PWE with no lesions, focal lesions, unilateral multifocal lesions and bilateral lesions across the three modalities results revealed statistically significant differences ( < 0.05). Among 61 PWE with interictal epileptiform discharges (IEDs) detected by AEEG, the agreement rate between SPECT/CT and AEEG was 63.93% (39/61), while that of 3D-pCASL was 39.34%(24/61), the difference is statistically significant ( = 0.007). In PWE with AEEG-detected temporal lobe (43 cases) and frontal lobe (31 cases) IEDs, SPECT/CT exhibited higher agreement rate with AEEG compared to 3D-pCASL ( < 0.05).

CONCLUSION

SPECT/CT demonstrated a high positive detection rate and showed strong agreement with AEEG-positive results in PWE. The combined use of SPECT/CT, AEEG and 3D-pCASL significantly increased the positive detection rate. These findings highlight the advantages of SPECT/CT and combined modalities.

摘要

目的

分析单光子发射计算机断层扫描(SPECT)/计算机断层扫描(CT)、动态脑电图(AEEG)及三维伪连续动脉自旋标记(3D-pCASL)在癫痫患者(PWE)中的临床应用价值。

方法

本研究纳入了2021年12月至2023年9月在宁夏医科大学总医院接受治疗的98例PWE。比较SPECT/CT、AEEG及3D-pCASL的阳性检出率及特征。此外,分析SPECT/CT、3D-pCASL与AEEG阳性结果之间的一致性。

结果

SPECT/CT、AEEG及3D-pCASL检查的阳性检出率分别为77.55%(76/98)、62.24%(61/98)和54.08%(53/98)。SPECT/CT的阳性检出率高于AEEG(校正比值比[aOR]=1.165,95%可信区间[CI]:1.036 - 1.311,P=0.011)和3D-pCASL(aOR=1.265,95%CI:1.119 - 1.430,P<0.001),AEEG与3D-pCASL之间未观察到显著差异(aOR=0.922,95%CI:0.810 - 1.048,P=0.213)。在联合检查模式中,AEEG + SPECT/CT + 3D-pCASL的阳性检出率(93.88%,92/98)高于AEEG + 3D-pCASL(79.59%,78/98,P=0.003),但与AEEG + SPECT/CT(88.78%,87/98,P=0.204)相比无统计学显著差异。三种检查模式结果显示无病变、局灶性病变、单侧多灶性病变及双侧病变的PWE比例存在统计学显著差异(P<0.05)。在AEEG检测到发作间期癫痫样放电(IEDs)的61例PWE中,SPECT/CT与AEEG的一致性率为63.93%(39/61),而3D-pCASL为39.34%(24/61),差异有统计学意义(P=0.007)。在AEEG检测到颞叶(43例)和额叶(31例)IEDs的PWE中,SPECT/CT与AEEG的一致性率高于3D-pCASL(P<0.05)。

结论

SPECT/CT在PWE中显示出较高的阳性检出率,且与AEEG阳性结果具有较强的一致性。SPECT/CT、AEEG及3D-pCASL联合使用显著提高了阳性检出率。这些发现突出了SPECT/CT及联合检查模式的优势。