Azevedo Henrique, Neto Lia Lucas, Berhanu David
Faculdade de Medicina, Universidade de Lisboa, Lisbon, Portugal.
Neurologic Imaging Department, ULS Santa Maria, Lisbon, Portugal.
J Neuroimaging. 2025 Sep-Oct;35(5):e70083. doi: 10.1111/jon.70083.
To review the existing evidence on multiple timepoint assessments of optic nerve sheath diameter (ONSD) as an indicator of intraindividual variation of intracranial pressure (ICP).
A systematic search identified studies assessing intraindividual variation in ICP through multiple timepoint measurements of ONSD using ultrasonography. Meta-analysis of studies assessing intraindividual correlation coefficients between ONSD and ICP was performed using a random effects model, and we calculated the weighted correlation coefficient for the expected change in ICP associated with variations in ONSD.
A total of five studies, comprising 157 patients, were included in the review. ONSD was compared with invasive ICP measurement methods at multiple timepoints. Meta-analysis of intraindividual ONSD-ICP correlation demonstrated a correlation coefficient of 0.62 (CI: 0.50-0.71). Individual linear correlation analyses were performed in two of the studies, yielding correlation coefficients ranging from 0.79 to 1.00; however, widely variable individual slopes were found (1.51-41.43 mm/mmHg). ONSD variations ranged from 0.12 to 3.30 mm per 5 mmHg change in ICP, with a variation of 0.55 mm in adults with hypoxic brain injury and 0.77 mm in children with idiopathic intracranial hypertension.
Our findings indicate that ONSD significantly correlates with ICP, and longitudinal intraindividual assessment shows a predominantly linear correlation between both variables. A personalized ONSD-ICP correlation equation may enable accurate ICP prediction, making ONSD a useful tool for follow-up in patients with previous invasive ICP measurements, when adjusted to each patient's characteristics and pathologies.
回顾现有关于视神经鞘直径(ONSD)多时间点评估作为颅内压(ICP)个体内变化指标的证据。
通过系统检索,确定了使用超声通过对视神经鞘直径进行多时间点测量来评估颅内压个体内变化的研究。使用随机效应模型对评估视神经鞘直径与颅内压之间个体内相关系数的研究进行荟萃分析,并计算与视神经鞘直径变化相关的颅内压预期变化的加权相关系数。
本综述共纳入5项研究,涉及157例患者。在多个时间点将视神经鞘直径与有创颅内压测量方法进行比较。对视神经鞘直径 - 颅内压个体内相关性的荟萃分析显示相关系数为0.62(95%置信区间:0.50 - 0.71)。两项研究进行了个体线性相关分析,相关系数范围为0.79至1.00;然而,发现个体斜率差异很大(1.51 - 41.43毫米/毫米汞柱)。颅内压每变化5毫米汞柱,视神经鞘直径变化范围为0.12至3.30毫米,缺氧性脑损伤成人的变化为0.55毫米,特发性颅内高压儿童的变化为0.77毫米。
我们的研究结果表明,视神经鞘直径与颅内压显著相关,纵向个体内评估显示这两个变量之间主要呈线性相关。个性化的视神经鞘直径 - 颅内压相关方程可能有助于准确预测颅内压,使视神经鞘直径成为在先前进行有创颅内压测量的患者中进行随访的有用工具,前提是根据每个患者的特征和病理情况进行调整。