Suppr超能文献

镍钛形状记忆吻合器与微型钢板治疗Bartoníček-Rammelt III型和IV型后踝骨折疗效的比较分析

A comparative analysis of the therapeutic outcomes between nickel-titanium shape memory staples and miniplate for Bartoníček-Rammelt type III and IV posterior malleolar fractures.

作者信息

Cao Yuan, Zheng Hao, Gao Peng, Ge Jianjian, Liu Yong

机构信息

Clinical Medicine School of Shandong Second Medical University, Weifang, China.

Department of Orthopedics, Affiliated Hospital of Shandong Second Medical University, Weifang, China.

出版信息

Medicine (Baltimore). 2025 Sep 5;104(36):e44278. doi: 10.1097/MD.0000000000044278.

Abstract

Comparative clinical efficacy of nickel-titanium shape memory staples versus miniplate for Bartoníček-Rammelt type III and IV posterior malleolar fractures. A retrospective analysis of 47 consecutive patients treated between January 2022 and June 2024 documented operative time, intraoperative blood loss, fluoroscopy times, healing time, complications, postoperative fracture gap distance (mm), and articular surface step-off (mm) at the ankle joint. Ankle function was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, the Manchester-Oxford Foot Questionnaire (MOXFQ), and range of motion measurements at 3, 6, 12, and 14 months. There were no statistically significant differences in baseline characteristics between the 2 groups. The shape-memory alloy group exhibited significantly shorter operative time [65.0 (60.0, 70.0)], less intraoperative blood loss [40.0 (30.0, 50.0)], and fewer intraoperative fluoroscopy instances [5.0 (4.0, 6.0)] than the miniplate group, with all differences showing statistical significance (P < .05). Postoperative imaging examinations revealed no significant differences in the fracture gap distance and articular surface step height of the ankle joint between the 2 groups. At 3 months, 6 months, and the final follow-up, there were no statistically significant differences in the AOFAS ankle-hindfoot scores and MOXFQ scores between the 2 groups of patients (P > .05). At the final follow-up, the AOFAS ankle-hindfoot scores and MOXFQ scores of all patients showed statistically significant differences compared to those at 3 and 6 months postoperatively (P < .05). At the final follow-up, there were no statistically significant differences in the range of motion for ankle dorsiflexion, plantarflexion, inversion, or eversion between the 2 patient groups (P > .05). Both nickel-titanium shape memory staples and miniplates achieved good clinical outcomes in the treatment of Bartoníček-Rammelt type III and IV posterior malleolar fractures. Both methods maintained satisfactory fracture reduction and resulted in favorable functional recovery of the ankle joint. However, the nickel-titanium shape memory staples offered advantages in shorter operative time, reduced intraoperative blood loss, and fewer intraoperative fluoroscopy exposures.

摘要

镍钛形状记忆吻合器与微型钢板治疗Bartoníček-Rammelt III型和IV型后踝骨折的临床疗效比较。对2022年1月至2024年6月期间连续治疗的47例患者进行回顾性分析,记录手术时间、术中出血量、透视次数、愈合时间、并发症、术后骨折间隙距离(mm)和踝关节面台阶(mm)。使用美国矫形足踝协会(AOFAS)踝-后足评分、曼彻斯特-牛津足部问卷(MOXFQ)以及在3、6、12和14个月时的活动度测量来评估踝关节功能。两组患者的基线特征无统计学显著差异。形状记忆合金组的手术时间[65.0(60.0,70.0)]明显短于微型钢板组,术中出血量[40.0(30.0,50.0)]更少,术中透视次数[5.0(4.0,6.0)]也更少,所有差异均具有统计学意义(P < .05)。术后影像学检查显示,两组患者踝关节的骨折间隙距离和关节面台阶高度无显著差异。在3个月、6个月和最终随访时,两组患者的AOFAS踝-后足评分和MOXFQ评分无统计学显著差异(P > .05)。在最终随访时,所有患者的AOFAS踝-后足评分和MOXFQ评分与术后3个月和6个月时相比有统计学显著差异(P < .05)。在最终随访时,两组患者在踝关节背屈、跖屈、内翻或外翻的活动度方面无统计学显著差异(P > .05)。镍钛形状记忆吻合器和微型钢板在治疗Bartoníček-Rammelt III型和IV型后踝骨折方面均取得了良好的临床效果。两种方法均维持了满意的骨折复位,并使踝关节功能得到了良好恢复。然而,镍钛形状记忆吻合器在缩短手术时间、减少术中出血量和减少术中透视暴露方面具有优势。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验