Colombo T, Cicardi C, Peronace B, Pozzi M, Gordini V, Pellegrini A
G Ital Cardiol. 1985 Oct;15(10):974-82.
The purpose of the study was to analyze the medium-term results (late mortality, thromboembolism, valve failure) in patients who underwent bioprosthetic valve replacement at "A. De Gasperis" Cardiovascular Surgery Division. From October 1975 to December 1982, 195 patients were consecutively operated on and discharged (118 with mitral prosthesis, 54 with aortic prosthesis, 22 with mitral and aortic prosthesis, 1 with mitral and tricuspid prosthesis). We reviewed 115 (97.45%) of 118 patients with mitral prosthesis (mean follow-up 46.61 months) and 54 (100%) patients with aortic prosthesis (mean follow-up 38 months). Eleven late deaths (2.4%/pt-yr) and 13 thromboembolic events (2.8%/pt-yr) occurred in patients with mitral prosthesis, 6 late deaths (3.5%/pt-yr) and 5 thromboembolic events (2.9%/pt-yr) occurred in patients with aortic prosthesis. Actuarial survival curves and actuarial incidence of thromboembolic event-free patients at 5 years are, respectively, 91.2% and 87.3% in patients with mitral prosthesis, 82.8% and 86.3% in patients with aortic prosthesis. The risk factors for thromboembolism were analyzed. Reoperation was requested in 14 cases (10 mitral and 4 aortic prostheses) for prosthetic leak (6 patients) or valve failure (8 patients). In linearized terms, the rate of valve failure requiring reoperation is 1.3%/pt-yr for mitral prostheses and 1.1%/pt-yr for aortic prostheses. The medium-term results suggest that the bioprostheses are, at the present time, an effective choice to the mechanical prostheses, nevertheless they are not free from risks of thromboembolic complications.
本研究的目的是分析在“A. 德加斯佩里斯”心血管外科接受生物瓣膜置换术患者的中期结果(晚期死亡率、血栓栓塞、瓣膜功能衰竭)。1975年10月至1982年12月,连续有195例患者接受手术并出院(118例植入二尖瓣假体,54例植入主动脉瓣假体,22例同时植入二尖瓣和主动脉瓣假体,1例同时植入二尖瓣和三尖瓣假体)。我们回顾了118例二尖瓣假体患者中的115例(97.45%)(平均随访46.61个月)和54例主动脉瓣假体患者(100%)(平均随访38个月)。二尖瓣假体患者发生11例晚期死亡(2.4%/人年)和13例血栓栓塞事件(2.8%/人年),主动脉瓣假体患者发生6例晚期死亡(3.5%/人年)和5例血栓栓塞事件(2.9%/人年)。二尖瓣假体患者5年时的精算生存曲线和无血栓栓塞事件患者的精算发生率分别为91.2%和87.3%,主动脉瓣假体患者分别为82.8%和86.3%。分析了血栓栓塞的危险因素。14例(10例二尖瓣假体和4例主动脉瓣假体)因人工瓣膜渗漏(6例患者)或瓣膜功能衰竭(8例患者)而需要再次手术。以线性化计算,二尖瓣假体需要再次手术的瓣膜功能衰竭发生率为1.3%/人年,主动脉瓣假体为1.1%/人年。中期结果表明,目前生物瓣膜是机械瓣膜的有效替代选择,但仍存在血栓栓塞并发症的风险。