Tamura Yuto, Ozu Kentaro, Oka Takafumi, Sekihara Takayuki, Ohtani Tomohito, Sakata Yasushi
Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
Department of Cardiovascular Medicine, Higashiosaka Medical Center, Higashiosaka, Osaka, Japan.
J Cardiol Cases. 2025 Jun 21;32(3):114-118. doi: 10.1016/j.jccase.2025.06.002. eCollection 2025 Sep.
In catheter ablation for outflow tract premature ventricular contraction (PVC), electrical mapping of the aortic sinus cusp (ASC) provides critical information for identifying the origin of the PVC. The OCTARAY™ (Biosense Webster, Diamond Bar, CA, USA), a multispline 48-polar electrode catheter with TRUEref™ technology, fits the shape of the ASC and enables detailed and prompt high-resolution ASC mapping without inducing PVCs due to mechanical stimulation. We present a case of successful catheter ablation for two similar PVCs from the ASC based on activation and voltage mapping using TRUEref™ technology. High-resolution mapping could be helpful for the visual assessment of the detailed wavefront propagations of PVC.
In catheter ablation for outflow tract premature ventricular contraction (PVC), mapping the aortic sinus cusp is useful to identify the origin; however, it is sometimes challenging with a conventional electrode catheter. High-resolution mapping using OCTARAY™ might be helpful for detailed assessment of outflow tract PVC.
在流出道室性早搏(PVC)的导管消融中,主动脉窦嵴(ASC)的电标测为确定PVC的起源提供了关键信息。OCTARAY™(美国加利福尼亚州钻石吧市的百盛韦伯斯特公司)是一种采用TRUEref™技术的多曲线48极电极导管,它能贴合ASC的形状,无需因机械刺激诱发PVC,即可实现详细且快速的高分辨率ASC标测。我们报告了一例基于使用TRUEref™技术的激动标测和电压标测,成功对来自ASC的两个相似PVC进行导管消融的病例。高分辨率标测有助于直观评估PVC详细的波前传播。
在流出道室性早搏(PVC)的导管消融中,标测主动脉窦嵴有助于确定起源;然而,使用传统电极导管有时具有挑战性。使用OCTARAY™进行高分辨率标测可能有助于详细评估流出道PVC。