Suppr超能文献

用于评估社区中风患者运动行为的便携式RISE设备的标准效度和结构效度。

Criterion and Construct Validity of the Pocket-Worn RISE Device to Assess Movement Behaviour in Community-Dwelling People with Stroke.

作者信息

Biemans Camille F M, van der Heiden Laura, Veenhof Cindy, Verschuren Olaf W, Visser-Meily Johanna M A, Pisters Martijn F, Hartman Yvonne A W

机构信息

Department of Rehabilitation, Physiotherapy Science & Sport, UMC Utrecht Brain Centre, University Medical Centre Utrecht, Utrecht University, 3584 CXUtrecht, The Netherlands.

Research Group Empowering Healthy Behaviour, Department of Health Innovations and Technology, School of Health Sciences, Fontys University of Applied Sciences Physiotherapy, 5612 MA Eindhoven, The Netherlands.

出版信息

Sensors (Basel). 2025 May 24;25(11):3308. doi: 10.3390/s25113308.

Abstract

Accurate monitoring of physical activity (PA) and sedentary behaviour (SB) is crucial for tailoring interventions aimed at improving movement behaviour. This study evaluated the validity of the pocket-worn RISE device for measuring movement behaviour in community-dwelling patients with stroke. Criterion validity was assessed in a laboratory setting using video recordings. Construct validity was assessed in a free-living setting using the thigh-affixed ActivPAL. In the laboratory setting (25 participants, 66 ± 11.8 years), the RISE device showed good criterion validity for SB and PA. In the free-living setting (19 participants, 73 ± 10.2 years), the RISE device showed good construct validity for SB and PA, though further improvements could enhance the accuracy of individual-level measurements of moderate to vigorous physical activity (MVPA) and prolonged sedentary bouts. The mean absolute percentage error and mean percentage error were below the predefined 20% threshold for SB and PA. Intraclass correlation coefficients (ICCs) for SB and PA showed good reliability, but ICC ranges for prolonged sedentary bouts and MVPA were too broad to draw firm conclusions. These findings indicate the RISE device is well-suited for measuring SB and PA in free-living conditions. With real-time feedback, app compatibility, and pocket-wear convenience, the RISE device shows potential for behavioural interventions targeting movement behaviour in stroke and other chronic conditions.

摘要

准确监测身体活动(PA)和久坐行为(SB)对于制定旨在改善运动行为的干预措施至关重要。本研究评估了口袋式RISE设备在测量社区中风患者运动行为方面的有效性。在实验室环境中使用视频记录评估标准效度。在自由生活环境中使用固定在大腿上的ActivPAL评估结构效度。在实验室环境中(25名参与者,66±11.8岁),RISE设备在测量SB和PA方面显示出良好的标准效度。在自由生活环境中(19名参与者,73±10.2岁),RISE设备在测量SB和PA方面显示出良好的结构效度,不过进一步改进可以提高中度至剧烈身体活动(MVPA)和长时间久坐行为个体水平测量的准确性。SB和PA的平均绝对百分比误差和平均百分比误差低于预先设定的20%阈值。SB和PA的组内相关系数(ICC)显示出良好的可靠性,但长时间久坐行为和MVPA的ICC范围过宽,无法得出确凿结论。这些发现表明,RISE设备非常适合在自由生活条件下测量SB和PA。凭借实时反馈、应用程序兼容性和口袋佩戴的便利性,RISE设备在针对中风和其他慢性病患者运动行为的行为干预方面显示出潜力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验