BOLD fMRI at 9.4T with 3D stack-of-spirals readouts.

作者信息

Monreal-Madrigal Alejandro, Kurban Denizhan, Tse Desmond H Y, Ivanov Dimo, Boulant Nicolas, Poser Benedikt A

机构信息

Maastricht Brain Imaging Centre, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, The Netherlands.

Scannexus BV, Maastricht, The Netherlands.

出版信息

MAGMA. 2025 Sep 29. doi: 10.1007/s10334-025-01298-4.

Abstract

OBJECTIVE

To investigate the use of spiral readouts for sub-millimeter BOLD fMRI at 9.4T and to verify simulations of the BOLD point spread function (PSF) with functional experiments.

MATERIALS AND METHODS

Spiral readouts were evaluated through simulations and functional experiments to test their performance in sub-millimeter BOLD fMRI. Both spiral-out and spiral-in readout strategies were considered, with attention to echo time (TE) relative to T*.

RESULTS

We confirmed that a TE shorter than T* can be employed for spiral-out readouts without compromising BOLD sensitivity. The use of shorter TE provided a reduced repetition time (TR), improved temporal signal-to-noise ratio (tSNR), and minimized off-resonance effects.

DISCUSSION

Spiral-in readouts were found to be mainly useful for lower-resolution applications at ultra-high field (UHF). In contrast, segmented spiral-out readouts demonstrated strong potential for mesoscopic BOLD fMRI at ultra-high fields (> 7T).