Suppr超能文献

[Determination of 51 per- and polyfluoroalkyl substances in raw water and drinking water by online solid-phase extraction coupled with ultra performance liquid chromatography- tandem mass spectrometry].

作者信息

Chen Yong-Yan, Lyu Jia, Ye Bi-Xiong, Zhang Lan, Wang Yuan-Yuan, Jin Ning

机构信息

China CDC Key Laboratory of Environment and Population Health,National Institute of Environmental Health,Chinese Center for Disease Control and Prevention,Beijing 100050,China.

出版信息

Se Pu. 2025 Nov;43(11):1222-1234. doi: 10.3724/SP.J.1123.2024.12020.

Abstract

In this study, an online solid-phase extraction-ultra performance liquid chromatography-tandem mass spectrometry (online SPE-UPLC-MS/MS) method was established to rapidly screen and determine 51 per- and polyfluoroalkyl substances (PFASs) in raw and drinking water. Ammonium formate and 24 PFAS internal standards were added to each sample. The ammonium formate concentration in the sample was 2 mmol/L after mixing, and the contents of the PFAS internal standards ranged between 2.5 and 50 ng/L. Each sample was filtered through a 0.22-μm cellulose acetate filter, and a 5-mL aliquot was injected and adsorbed using an HLB online solid-phase extraction column and rinsed with 2 mmol/L ammonium formate. Acetonitrile and 2 mmol/L aqueous ammonium formate were used as mobile phases. Separation was performed on a BEH C chromatographic column with gradient elution. Electrospray ionization source negative ion mode and multiple reaction monitoring mode were used for detection, with quantification performed using the internal standard method. The method was validated by determining accuracies and precisions for the 51 PFASs using raw water and drinking water as matrices. Excellent linear relationships within their respective ranges were observed, with correlation coefficients ()>0.995. The method exhibited limits of detection (LODs, =3) and quantification (LOQs, =10) of 0.03-1.5 and 0.1-5.0 ng/L, respectively. The PFASs were spiked at levels of 1, 10 and 50 ng/L, with spiked recoveries of 60.2%-126.9% and 60.4%-122.6% obtained for raw- and drinking-water samples, respectively, along with corresponding relative standard deviations (RSDs, =6) of 0.3%-17.9% and 0.4%-17.7%, respectively. The developed method was used to determine PFAS residues in raw and drinking water, with perfluoroalkyl carboxylic acids, perfluoroalkyl sulfonic acids, and perfluoroalkyl ether acids detected at relatively high rates with contents of 0.1-209.7 and 0.1-63.6 ng/L in raw water and drinking water, respectively. Compared to offline solid-phase extraction methods, the developed method requires fewer samples, is more convenient from a sample-collection perspective, and uses lower quantities of internal standards. It also analyzes rapidly and is highly sensitive and reproducible. Only 20 min was required to determine the 51 PFASs at the ng/L level, from online enrichment to detection. The developed method is suitable for the trace determination of various types of PFAS, such as perfluoroalkyl carboxylic acids, perfluoroalkyl sulfonic acids, perfluoroalkyl ether acids, fluorotelomers, and fluoroalkyl sulfonamides, in raw and drinking water, thereby effectively boosting the detection efficiency for perfluoroalkyl substances in water in a manner that has substantial practical applications value.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/baaf/12598546/fb220044d951/A422A59A-4640-4eef-B97F-592FF70A0D18-F001.jpg

相似文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验