Suppr超能文献

与放射治疗相关的不同快中子束的剂量积累和深度剂量特性。

Build-up and depth-dose characteristics of different fast neutron beams relevant for radiotherapy.

作者信息

Mijnheer B J

出版信息

Br J Radiol. 1978 Feb;51(602):122-6. doi: 10.1259/0007-1285-51-602-122.

Abstract

Build-up and central axis depth-dose curves have been obtained for d(50) + Be and d + T neutron beams. Measurements carried out with the collimator opening covered with a layer of lead showed that for all three neutron beams the entrance dose is approximately 60% of the dose at the maximum. Consequently the skin-sparing properties of these neutron beams will be approximately equal and comparable to those for electron beam therapy. Central axis depth-dose curves have been established for d(50) + Be neutrons at 129 cm SSD, for p(42) + Be neutrons at 125 cm SSD and d + T neurtons and 60Co gamma rays at 80 cm SSD. The 50% dose values in a water phantom are at depths of 12.7 cm, 12.0 cm, 9.7 cm and 12.7 cm respectively, for field sizes of approximately 15 cm x 20 cm. Insertion of a 6 cm thick nylon filter in the p(42)+Be beam increases this value from 12.0 cm to 13.5 cm. The gamma component for the d+T neutron beam is higher than for the cyclotron beams.

摘要

已获得d(50)+铍和氘+氚中子束的累积剂量曲线和中心轴深度剂量曲线。用一层铅覆盖准直器开口进行的测量表明,对于所有这三种中子束,入口剂量约为最大剂量的60%。因此,这些中子束的皮肤保护特性将大致相同,并且与电子束治疗的特性相当。已建立了在129厘米源皮距下d(50)+铍中子、在125厘米源皮距下p(42)+铍中子以及在80厘米源皮距下氘+氚中子和60钴γ射线的中心轴深度剂量曲线。对于约15厘米×20厘米的射野尺寸,在水模体中的50%剂量值分别位于12.7厘米、12.0厘米、9.7厘米和12.7厘米的深度处。在p(42)+铍束中插入一个6厘米厚的尼龙滤过器可使该值从12.0厘米增加到13.5厘米。氘+氚中子束的γ成分高于回旋加速器束的γ成分。