Suppr超能文献

间接荧光抗体技术中全抗血清与抗血清γ-球蛋白组分的比较

Whole antiserum versus the gamma-globulin fraction of antiserum in the indirect fluorescent antibody technique.

作者信息

Myers J, Sargent A U, Cohen J J

出版信息

Immunology. 1965 Aug;9(2):101-5.

Abstract

Two antisera were compared with their γ-globulin fractions for their effectiveness as the middle or unlabelled layer in the indirect fluorescent antibody technique. The γ-globulin fraction did not produce better results in either case than the equivalent concentration of whole serum. Control sections were prepared with normal rabbit serum substituted for the whole antiserum and with normal rabbit γ-globulin substituted for the γ-globulin fraction of the antiserum. The control sections with γ-globulin showed considerably more non-specific fluorescence than those with whole serum. In one case the non-specific fluorescence in the γ-globulin control interfered with interpretation of the experimental section.

摘要

比较了两种抗血清及其γ球蛋白组分作为间接荧光抗体技术中层或未标记层的有效性。在这两种情况下,γ球蛋白组分产生的结果均不比等量浓度的全血清更好。用正常兔血清替代全抗血清,并用正常兔γ球蛋白替代抗血清的γ球蛋白组分制备对照切片。与全血清对照切片相比,γ球蛋白对照切片显示出更多的非特异性荧光。在一种情况下,γ球蛋白对照中的非特异性荧光干扰了实验切片的解读。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/aabf/1423705/9e605f5f7622/immunology00427-0009-a.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验