Biedermann M, Büttner G, Kaschowitz H, Pingel I
Acta Biol Med Ger. 1977;36(7-8):1097-105.
The influence of highly intensive single impulses on the cochlea of guinea pig was studied in an acute experiment. Very short impulses of less than or equal to 0.1 ms duration were produced by a sparknoise generator. The cochlear microphonics (CM) to a test stimulus (sinus tone, 3150 Hz) were recorded from the round window and measured prior to, during, and following impulse treatment. During the impulse treatment, the greatest amplitude reduction of CM occurred after the first impulse, while the further impulses caused a decreasing reduction. At first the number of impulses was varied: 1, 3, and 5 impulses were applied at intervals of 15 s each, at an impulse sound level of 164 dB sound pressure level re. 0.002 mubar (SPL). After these impulse treatments, in all cases a continual decrease of CM amplitudes up to a constant end value without recovery was found within a 2-hrs period of observation. The height of the end value depends on the number of impulses applied. Subsequently, at an exposure to 5 impluses the impulse sound level was stepwise reduced (164, 153, 144, 139 and 133 dB SPL). Again, a characteristic decrease of CM amplitudes was observed during the 2-hrs period of observation. The height of the end value is now dependent on the impluse sound level. Impulses of 164, 153 and 144 dB SPL cause a strong decrease of CM while the effect of impulses of 139 and 133 dB SPL is distinctly lower.
在急性实验中研究了高强度单个脉冲对豚鼠耳蜗的影响。由火花噪声发生器产生持续时间小于或等于0.1毫秒的极短脉冲。从圆窗记录对测试刺激(3150赫兹正弦音)的耳蜗微音器电位(CM),并在脉冲处理前、处理期间和处理后进行测量。在脉冲处理期间,CM的最大幅度降低发生在第一个脉冲之后,而后续脉冲导致的幅度降低逐渐减小。首先改变脉冲数量:以164分贝声压级(相对于0.002微巴)的脉冲声级,每隔15秒施加1、3和5个脉冲。在这些脉冲处理后,在所有情况下,在2小时的观察期内发现CM幅度持续下降直至达到恒定的终值且无恢复。终值的高度取决于施加的脉冲数量。随后,在施加5个脉冲时,逐步降低脉冲声级(164、153、144、139和133分贝声压级)。同样,在2小时的观察期内观察到CM幅度有特征性下降。现在终值的高度取决于脉冲声级。164、153和144分贝声压级的脉冲会导致CM大幅下降,而139和133分贝声压级的脉冲的影响明显较低。