Johnson S B, Coakes R L, Brubaker R F
Am J Ophthalmol. 1978 Apr;85(4):469-74. doi: 10.1016/s0002-9394(14)75243-2.
We devised a convenient method of measuring anterior chamber volume in man. Photographs of the anterior chamber were taken with a Zeiss photographic slit lamp with a Polaroid attachment, and measured with a specially constructed transparent scale. Using this method, the standard deviation of individual measurements of volume on different occasions in a given eye was 8 microliter. The standard deviation of the differences between right and left eyes of normal subjects was 10 microliter. The volume of the anterior chamber measured in 78 eyes of 39 normal subjects (mean age, 28 years; range, 19 to 56 years) was found to be 209 +/- 37 microliter (mean +/- SD). We observed a small negative correlation between the age of the subject and the volume of the anterior chamber.
我们设计了一种测量人体前房容积的简便方法。使用带有宝丽来附件的蔡司摄影裂隙灯拍摄前房照片,并用特制的透明标尺进行测量。采用这种方法,在给定眼睛的不同时间进行的个体容积测量的标准差为8微升。正常受试者左右眼之间差异的标准差为10微升。在39名正常受试者(平均年龄28岁;范围19至56岁)的78只眼中测量的前房容积为209±37微升(平均值±标准差)。我们观察到受试者年龄与前房容积之间存在微弱的负相关。