Abstract

The use of polyacrylamide gel electrophoresis as a screening procedure for the characterisation of hyperlipoproteinaemia is described. Sixty-one samples were investigated and classified by four different methods: (1) chemical profile derived from visual appearance and estimation of total cholesterol and triglyceride; (2) 'SML' profile by nephelometry; (3) electrophoresis on agarose gel; and (4) electrophoresis on polyacrylamide gel. Polyacrylamide gel electrophoresis showed the closest correlation with the chemical profile when compared with the other two methods. Polyacrylamide gel electrophoresis was found to be a rapid, reliable, and satisfactory procedure for plasma lipoprotein phenotyping.

摘要

本文描述了使用聚丙烯酰胺凝胶电泳作为一种筛选方法来鉴定高脂蛋白血症。研究了61个样本,并通过四种不同方法进行分类:(1) 根据外观以及总胆固醇和甘油三酯的估计得出的化学图谱;(2) 用比浊法测定的“SML”图谱;(3) 在琼脂糖凝胶上进行电泳;以及(4) 在聚丙烯酰胺凝胶上进行电泳。与其他两种方法相比,聚丙烯酰胺凝胶电泳与化学图谱的相关性最为密切。结果发现,聚丙烯酰胺凝胶电泳是一种用于血浆脂蛋白表型分析的快速、可靠且令人满意的方法。