Arnold B A, Eisenberg H, Bjarngard B E
Radiology. 1979 Jun;131(3):743-9. doi: 10.1148/131.3.743.
Image quality and radiation exposures of a mammographic technique using direct radiographic magnification at 2 X with a microfocal spot x-ray tube and a fast, double screen-film system were compared to those of conventional contact mammography with a rare-earth screen and molybdenum target tube. The results indicate that the magnification technique yields improved detection of microcalcifications and comparable visualization of soft-tissue details, with a large reduction in radiation exposure. This technique has demonstrated the feasibility of carrying out high-quality mammography with an entrance dose of 1.35 X 10(-3) Gy (135 mrad) for the average breast.
将使用微焦点X射线管和快速双屏-胶片系统进行2倍直接射线照相放大的乳腺摄影技术的图像质量和辐射剂量,与使用稀土屏和钼靶管的传统接触式乳腺摄影的图像质量和辐射剂量进行了比较。结果表明,放大技术能更好地检测微钙化,软组织细节的可视化效果相当,且辐射剂量大幅降低。该技术已证明,对于平均乳腺,以1.35×10⁻³戈瑞(135毫拉德)的入射剂量进行高质量乳腺摄影是可行的。