Six healthy young men sustaining femoral shaft fractures in traffic accidents were treated in pins-in-plaster. Complications included pintract infection (3/6), shortening, angulation (1), malrotation (2). Recasting and rehospitalization was frequent. These adverse experiences with this method of treatment of femoral shaft fractures should discourage its further use.
6名在交通事故中发生股骨干骨折的健康青年男性接受了石膏托加针固定治疗。并发症包括针道感染(3/6)、短缩、成角(1例)、旋转畸形(2例)。频繁需要重新打石膏和再次住院。股骨干骨折这种治疗方法的这些不良经历应使其不再被进一步使用。