Robohm R A
Appl Microbiol. 1974 Jan;27(1):179-84. doi: 10.1128/am.27.1.179-184.1974.
Quantitative measurements of the effects of ions on fluorescent antibody reactions have not been reported in the literature. Data in this report show the effects of ranges of H(+), phosphate, Mg(2+), and Ca(2+) molarities on antigen-antibody coupling during an indirect fluorescent antibody (IFA) reaction for Clostridium botulinum type E. These effects were quantified in two ways: (i) by microphotometric measurement of cell fluorescence intensity; and (ii) by visual estimation of cell fluorescence intensity on long glass strips treated with antibody in ion gradients. Optimal pH for the first part of the reaction (coupling of rabbit antibody to cells) was 7.25, and optimum in the second part (coupling of tracer globulin to the rabbit globulin) was pH 7.37. Running the reaction as little as 0.10 to 0.15 pH units off from the optima considerably reduced fluorescence intensity. Sodium phosphate buffer up to 0.1 M did not significantly affect either portion of the reaction. Ca(2+) and Mg(2+) showed no effect on the first part of the reaction. These results support the use of higher-strength phosphate buffer and indicate for the first time that IFA reactions may have two independent, narrow pH optima.
关于离子对荧光抗体反应影响的定量测量在文献中尚未见报道。本报告中的数据显示了H⁺、磷酸盐、Mg²⁺和Ca²⁺摩尔浓度范围对E型肉毒梭菌间接荧光抗体(IFA)反应期间抗原 - 抗体偶联的影响。这些影响通过两种方式进行定量:(i)通过显微光度测量细胞荧光强度;(ii)通过目视估计在离子梯度中用抗体处理的长玻璃条上的细胞荧光强度。反应第一部分(兔抗体与细胞的偶联)的最佳pH为7.25,第二部分(示踪球蛋白与兔球蛋白的偶联)的最佳pH为7.37。反应偏离最佳值仅0.10至0.15个pH单位就会显著降低荧光强度。高达0.1 M的磷酸钠缓冲液对反应的任何一部分均无显著影响。Ca²⁺和Mg²⁺对反应的第一部分没有影响。这些结果支持使用更高强度的磷酸盐缓冲液,并首次表明IFA反应可能有两个独立的、狭窄的pH最佳值。