Suppr超能文献

单侧无晶状体眼的融合及影像不等问题(作者译)

[Fusion and aniseikonic problems in unilateral aphakia (author's transl)].

作者信息

Dannheim E, Retzlaff H U

出版信息

Klin Monbl Augenheilkd. 1979 Apr;174(4):629-34.

PMID:459333
Abstract

In 67 unilateral aphakic patients corrected with three different optic systems (conventional contact lens, spheric overcorrection and intraocular lens) aniseikonia and binocular vision are tested. Conventional contact lens leads to 7% aniseikonia and to fusion in only half of the cases. Patients with the two other systems show less than 3% aniseikonia and fusion in most cases. With each system only 10% of the patients reach normal stereoscopic vision. The poor results in unilateral aphakia corrected by conventional contact lens are pointed out.

摘要

在67例接受三种不同光学系统(传统隐形眼镜、球镜过矫和人工晶状体)矫正的单侧无晶状体患者中,对不等像和双眼视觉进行了测试。传统隐形眼镜导致7%的不等像,且仅在半数病例中实现融合。使用其他两种系统的患者在大多数情况下不等像小于3%且实现融合。每种系统仅有10%的患者达到正常立体视觉。文中指出了传统隐形眼镜矫正单侧无晶状体效果不佳的情况。