Perforation of the femoral shaft by the stem of the prosthesis is a rare, but serious complication following total hip replacement. It is a complication that is avoidable if meticulous attention is given to preoperative planning and intraoperative technique. The major predisposing factors for this complication are previous hip surgery, hip dysplasia, osteoporosis and poor exposure. Every attempt should be made to discover a perforation during surgery and to correct the alignment of the femoral stem. The patients who have experienced this complication have had a poor result suffering pain, loosening or femoral shaft fracture necessitating surgical revision.
假体柄穿入股骨干是全髋关节置换术后一种罕见但严重的并发症。如果在术前规划和术中技术方面给予精心关注,这种并发症是可以避免的。该并发症的主要诱发因素是既往髋关节手术、髋关节发育不良、骨质疏松和暴露不佳。手术中应尽一切努力发现穿孔并纠正股骨干假体的对线。发生这种并发症的患者预后较差,会遭受疼痛、松动或股骨干骨折,需要进行手术翻修。