Suppr超能文献

525只无晶状体眼中的长戴型隐形眼镜。

Extended-wear contact lenses in 525 aphakic eyes.

作者信息

Boyd B F

出版信息

Am J Ophthalmol. 1979 Sep;88(3 Pt 1):351-3. doi: 10.1016/0002-9394(79)90632-9.

Abstract

Extended-wear contact lenses were fitted to 225 patients with monocular aphakia and 150 with bilateral aphakia. They were observed from three months to three years. Eighty-eight of the 195 eyes fitted with a Softcon lens became red and painful within 14 days during extended wear. The Hydrocurve lens was better tolerated in 55, but many patients had acute congestion, pain, and tearing. Deposits accumulated rapidly on the Sauflon-PW lens. Some 90% of all patients can be fitted successfully with the cellulose acetate butyrate lens or the silicone lens. The silicone coating of the silicone lens is lost or damaged in about 20% of the patients because of excess mucous accumulation.

摘要

为225名单眼无晶状体患者和150名双眼无晶状体患者佩戴了长戴型隐形眼镜。对他们进行了3个月至3年的观察。在长戴期间,195只佩戴Softcon镜片的眼睛中有88只在14天内出现眼红、疼痛。55只佩戴Hydrocurve镜片的眼睛耐受性较好,但许多患者出现急性充血、疼痛和流泪。Sauflon - PW镜片上沉积物迅速积聚。约90%的患者可以成功佩戴醋酸丁酸纤维素镜片或硅树脂镜片。由于黏液过度积聚,约20%的患者硅树脂镜片的硅树脂涂层会脱落或受损。

相似文献

1
Extended-wear contact lenses in 525 aphakic eyes.525只无晶状体眼中的长戴型隐形眼镜。
Am J Ophthalmol. 1979 Sep;88(3 Pt 1):351-3. doi: 10.1016/0002-9394(79)90632-9.
2
Extended-wear Hydrocurve and Sauflon contact lenses.长戴型Hydrocurve和索芙伦隐形眼镜。
Am J Ophthalmol. 1980 Sep;90(3):309-16. doi: 10.1016/s0002-9394(14)74909-8.
3
Extended-wear soft contact lenses for aphakic correction.用于无晶状体眼矫正的长戴型软性隐形眼镜。
Arch Ophthalmol. 1983 Jan;101(1):39-41. doi: 10.1001/archopht.1983.01040010041003.
7
Extended wear contact lenses for aphakia.
Am J Optom Physiol Opt. 1981 Jun;58(6):467-71. doi: 10.1097/00006324-198106000-00006.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验